background image

PLUTONE ’09 v01 

pag. 7 

marzo 2009 

4.

 

For dry ironing it is possible to adjust the thermostat 

(fig. 2)

 on different positions 

according to the type of fabric (check garment label). For steam ironing you should 
adjust the thermostat on “cotton/flax” position. 

 

 
 

 

11.

 

ELECTRICAL RISKS 

 

 
The following situations are considered dangerous for the operator: 

 

1.

 

damage of iron cables 

(fig. 2)

2.

 

loss of water from iron 

(fig. 3)

3.

 

loss of water from external of solenoid valve 

(fig. 1)

4.

 

iron overheating, 

5.

 

earth protector switch is activated upon turning on the main switch, 

6.

 

using PLUTONE during thunderstorms, 

7.

 

using  PLUTONE  without  proper  protection  for  feet  (without  shoes)  or  with  wet 

feet, 

8.

 

cleaning or washing the iron using water 

(fig. 3)

9.

 

loss of water from PLUTONE base 

(fig. 1)

10.

 

loss of steam from inner part of PLUTONE. 

 

 

12.

 

MECHANICAL RISKS

 

 
The following situations are considered dangerous for the operator: 

1.

 

using PLUTONE for different purposes other than ironing; 

2.

 

using PLUTONE without turning the water tap or when the aqueduct cannot supply 

water; 

3.

 

using PLUTONE while the pump is activated but no water enters the boiler because 
of limestone obstruction 

(fig. 1)

4.

 

using PLUTONE when the boiler pressure is too high and the internal safety valve is 
activated.  Pressure  can  be  visibly  controlled  thanks  to  the  manometer 

(fig.1)

 

placed on the upper part of the  PLUTONE. 

 

13.

 

THERMAL RISKS

 

 

The following situations are considered dangerous for the operator: 

 
1.

 

touching the iron base when it is functioning, 

2.

 

emptying the boiler when under pressure 

(fig. 1)

 

ELECTRICAL
WIRE

THERMOSTAT

MICROSWITCH
FOR IRON

STEAM HOSE

 

Fig. 3 

Fig. 2 

Содержание PLUTONE 2009

Страница 1: ...LLED POWER W 5648 W 5970 POWER OF IRON 1 W 800 W 800 POWER OF IRON 2 W 800 W 800 BOILER POWER W 4000 W 4000 PUMP POWER W 48 Hp 0 5 BOILER CAPACITY 5 L 5 L IRONING ENDURANCE CONTINUOUS CONTINUOUS OPERA...

Страница 2: ...protected electrical outlet suitable to PLUTONE power 3 OPENING OF PACKAGE 1 Open the box containing PLUTONE from the upper side marked as ALTO take out the instructions handbook and read it carefull...

Страница 3: ...NTERMITTENT LIGHT indicates that the boiler is on and that the water is being heated to obtain steam Indicates that iron 1 is functioning Indicates that iron 2 is functioning Indicates that the pump i...

Страница 4: ...4 times fig 3 so that steam comes out this operation must be carried out in order to heat up the hoses which take steam to the iron This prevents also the falling of small drops of water on garments...

Страница 5: ...RESET OF WARNINGS Ok FILTER Zeroing of hours SET Reset Ok To exit Esc COVER PROBE Reset is necessary in order to delete the warnings from the display once maintenance has been done Example WARNING PRO...

Страница 6: ...nly when the boiler is cold and the plug is disconnected from the mains 3 Never leave hot iron on the ironing board 4 Connect PLUTONE to a suitable and protected outlet 5 After ironing is over switch...

Страница 7: ...water fig 3 9 loss of water from PLUTONE base fig 1 10 loss of steam from inner part of PLUTONE 12 MECHANICAL RISKS The following situations are considered dangerous for the operator 1 using PLUTONE f...

Страница 8: ...off and are cold fig 2 4 cleaning of the water inlet filter fig 4 and cleaning of the foot valve filter PLUTONE with water tank fig 1 15 CLEANING OF WATER FILTER The cleaning of the filter is to be do...

Страница 9: ...ERIODICAL MAINTENANCE TO BE CARRIED OUT EXCLUSIVELY BY AUTHORIZED SERVICE CENTRES QUALIFIED TECHNICIANS OR BY THE MANUFACTURER Compulsory maintenance is signalled by the icon GENERAL MAINTENANCE will...

Страница 10: ...osal and recycling of the machine s components assures protection of the natural environment Every product manufactured by BATTISTELLA B G S r l is subject to the following limitations Battistella B G...

Отзывы:

Похожие инструкции для PLUTONE 2009