Rev. A-021210
Page 1
P/N VDC E12248-S2-MNL
BatteryMINDer
®
E12248-AA-S2
Note
: If the battery does not have a minimum no load OCV
(Open Circuit Voltage) of 6 volts, the ERROR LED will light
RED
and charger will reject battery.
No further effort should be made to charge this battery with this
charger or any charger. Discard this battery, unless it has just
been subjected to a long period of continuous discharge under
a load such as can occur with leaving lights on or cranking an
engine excessively. Allow such a battery to “Rest” for several
hours (overnight if possible) before determining if it is defective.
Be very suspicious of any 12-V battery that does not have at
least 11-Volts (OCV) before it is recharged. It may well be seri-
ously damaged and unsafe for any type of use or recharge. The
unit’s Battery Condition Indication LED will help you determine if
battery is less than 11-Volts (
YELLOW
)) or greater than 11-Volts
(
GREEN
)
7.
After battery has been fully charged, the
GREEN
Charge-Float
LED Indicator will begin blinking. It will continue to blink indefi-
nitely, unless unit is disconnected from battery or Stop/Restart
button is pressed. Should battery be unable to be fully charged,
the LED will not blink and the
RED
Error LED will blink. Battery
may not be able to be fully charged, may be too large or too
deeply discharged to be fully charged in the normal time allowed
by charger. If you are certain battery is not defective, having read
and understood completely all of the above concerns and condi-
tions, proceed to restart the charger by pressing and holding the
Stop/Restart button for approx. 5 seconds until all LEDs Flash.
This allows charger to begin charging battery again.