Rev. A-021009
P/N VDC24041AA-S3-MNL
BatteryMINDer
®
Model 24041-AA-S3
Page 28
3.
If recharging multiple batteries, 2 or more
complete recharge cycles may be needed.
Repeat full recharge by pressing START but-
ton again. If still
RED
-blinking, you may need to
charge each battery separately.
Problem
:
Battery Condition Indicator lights
YELLOW
(After battery has been completely charged)
Solution
:
Battery still has an unacceptable level of sulfation
and must stay connected to charger and remain
in Maintenance-Float mode (
GREEN
blinking
indicator) for 72 hours or longer. Then stop char-
ger by pressing Stop/Restart button and observe
Indicator. If still
YELLOW
repeat (up to 3 full
cycles) or until indicator lights
GREEN
.
Problem
:
Battery Condition Indicator lights
YELLOW
(May
be several causes)
(Before battery is completely charged)
Solution
.
Battery can be weak due to sulfation, self dis-
charge or was very deeply discharged.
Attempt a full recharge and recheck after comple-
tion. If still
YELLOW
follow procedure for (After
battery has been completely charged.)
Problem
:
Error and Charge LEDs blink simultaneously
Solution
:
Charger has timed out before battery has com-
pletely charged. Reset unit. Repeat reset - full
recharge by pressing Stop/Restart button and
holding it down until ALL LEDs flash. Press Stop/
Restart button to begin full recharge.