Rev. A-021009
P/N VDC24041AA-S3-MNL
BatteryMINDer
®
Model 24041-AA-S3
Page 30
DETAILED SPECIFICATIONS - VDC Model No. 24041-AA-S3 (con’t.)
•
Charging Output Control Characteristics
•
Charging Flow : Battery condition detect>Soft Start Charge>Bulk Charge>Absorption
Charge>Sulfate Check>Float Charge
•
Soft Start Charging Activity conditions: Battery Voltage is over 6 Vdc and less than 21Vdc
•
Soft Start Charging output current control: 4 ±0.25 Adc
•
Soft Start Charging Time Limited: (Stops charge if battery cannot be charged over 21.0-V after
6 hrs, Error LED flash indicated) 6 ±0.25 Hours
•
Bulk Charging Activity conditions: Battery Voltage is over 21Vdc
•
Bulk Charging Current control:
4 +0.22 / -0 Adc
•
Max. rated output voltage and current: 27.2-V at 4Adc 27.2-V at 3.25Adc
•
Bulk Charging Time Limited: (Stops charge if battery cannot be fully charged [29.4-V*]
after 20 hrs, error LED flash indicated) 20 ±1 Hours
*At 25°C