2.0 Specifica ons
Measuring Principle
:
Electromagnetic flow measurement on the basis of Faraday’s Law.
Flow Range
:
0.03-10 m/s
Turndown Ra o
:
333:1
Size
:
10 to 2200 mm
Min. Conduc vity
:
5 micromhos/cm
Electrode Materials
:
Standard: AISI316L
Op onal: Tantalum,Titanium,Hastelloy B,Hastelloy C
Liner Material
:
PTFE, Hard Rubber,PA
Fluid Temperature
:
Hard Rubber : 0...60°C
PTFE : -20...120°C
PA : 0...60°C
Pressure Limits
:
DN10...DN80
PN40
DN100...DN350
PN16
DN350<
PN10
please consult Bass Instruments for special requirements.
Pressure Loss
:
No pressure loss
Coil Power
:
Pulsed DC
Ambient Temperature
:
-10°C to 60°C for carbon steel body
-30°C to 60°C for stainless steel body
Protec on
:
IP67,IP68 op onal for remote version” RM”
Pipe Spool Material
:
316 Stainless Steel
Sensor Housing Material
:
Carbon Steel welded,op onal AISI304,AISI316
Flanges
:
Carbon Steel - Standard (TS ISO 7005-1)
316 Stainless Steel – Op onal
Cable Length
:
up to 300 m (please see length of connec on cable)
Moun ng Posi on
:
Ver cal or Horizontal (please see installa on)