DECS-100 Installation
4-1
SECTION 4 • INSTALLATION
GENERAL
DECS-100 Digital Excitation Control Systems are delivered in sturdy cartons to prevent shipping damage.
Upon receipt of a system, check the Part Number against the requisition and packaging list for agreement.
Inspect for damage, and if there is evidence of such, immediately file a claim with the carrier and notify the
Basler Electric Regional Sales Office, your Sales Representative or a Sales Representative at Basler Electric,
Highland, Illinois.
If the unit is not installed immediately, store it in the original shipping package in a moisture and dust free
environment.
MOUNTING
The DECS-100 is normally located in the generator conduit box. It is designed for behind the panel mounting
and requires a cutout for front panel viewing. Mounting hardware consists of six customer supplied, #12
thread-forming screws that pass through mounting holes in the conduit box and thread into the plastic shell
of the DECS-100. The recommended torque range for the steel mounting screws is 20 to 24 inch-pounds
(2.26 to 2.71 Newton meters). The unit must be mounted where the ambient temperature does not exceed
the allowable environmental conditions called out in Section 1,
General Information, Specifications. DECS-
100 package dimensions are shown in Figure 4-1. Cutout and drilling dimensions are shown in Figure 4-2.
Drawing dimensions are shown in inches and millimeters (in parenthesis).