9252000990 Rev N
BE1-50/51M Installation
4-1
SECTION 4
•
INSTALLATION
GENERAL
When not shipped as part of a control or switchgear panel, the relays are shipped in sturdy cartons to
prevent damage during transit. Immediately upon receipt of a relay, check the model and part number
against the requisition and packing list to see that they agree. Visually inspect the relay for damage that
may have occurred during shipment. If there is evidence of damage, immediately file a claim with the
carrier and notify the Regional Sales Office, or contact the Sales Representative at Basler Electric,
Highland, Illinois.
Proper operation of the relay may be confirmed by performing the operational test procedure of Section 5.
If the relay won't be installed immediately, store the relay in its original shipping carton in a moisture and
dust-free environment.
MOUNTING
A rack mounting plate (part number 9252012001) can be purchased to mount four BE1-50/51M (vertical
mount) relays side-by-side in a standard 19 inch wide rack. The rack mounting plate is four rack units
(seven inches) high and is shown in Figure 4-1. A cover (part number 9252012101) is also available that
covers one mounting location. Relay outline dimensions and panel drilling diagrams are shown in Figures
4-2 and 4-3.
Figure 4-1. Rack Mounting Plate, Part Number 9252012001
Содержание BE1-50M
Страница 1: ...INSTRUCTION MANUAL FOR OVERCURRENT RELAY BE1 50 51M Publication 9252000990 Revision N 03 08 ...
Страница 2: ......
Страница 8: ...vi BE1 50 51M Introduction 9252000990 Rev N This page intentionally left blank ...
Страница 10: ...ii BE1 50 51M General Information 9252000990 Rev N This page intentionally left blank ...
Страница 22: ...ii BE1 50 51M Controls and Indicators 9252000990 Rev N This page intentionally left blank ...
Страница 28: ...ii BE1 50 51M Functional Description 9252000990 Rev N This page intentionally left blank ...
Страница 32: ...ii BE1 50 51M Installation 9252000990 Rev N This page intentionally left blank ...
Страница 37: ...9252000990 Rev N BE1 50 51M Installation 4 5 Figure 4 5 DC Control Connections ...
Страница 38: ...4 6 BE1 50 51M Installation 9252000990 Rev N Figure 4 6 BE1 50 51M Terminal Connections Rear View ...
Страница 40: ...4 8 BE1 50 51M Installation 9252000990 Rev N This page intentionally left blank ...
Страница 42: ...ii BE1 50 51M Testing 9252000990 Rev N This page intentionally left blank ...
Страница 50: ...5 8 BE1 50 51M Testing 9252000990 Rev N This page intentionally left blank ...
Страница 52: ...ii BE1 50 51M Relay Differences 9252000990 Rev N This page intentionally left blank ...
Страница 56: ...6 4 BE1 50 51M Relay Differences 9252000990 Rev N This page intentionally left blank ...
Страница 58: ...ii BE1 50 51M Time Characteristic Curves 9252000990 Rev N This page intentionally left blank ...