Basler A600f Скачать руководство пользователя страница 7

Supplement

Basler A600f Board Level

1

DRAFT

1

Purpose of This Document

Basler A600f Board Level cameras are variants of standard Basler A600f cameras. The purpose
of this document is to describe the features unique to A600f Board Level cameras.

The unique features of A600f Board Level cameras are listed below.

• As the name implies, A600f Board Level cameras consist of electronic parts and a sensor

mounted on a circuit board. The cameras are not enclosed in a housing. The drawings in
Section 

3

 show the dimensions of the board and the location of the sensor.

Standard A600f cameras are always enclosed in a housing.

• Because Board Level cameras do not include a housing, they are not tested for EMI. Section

2

 has more information about EMI testing.

Standard A600f cameras are tested and certified for EMI.

• Board Level cameras are available with a C-mount lens adapter attached to the circuit board.

They are also available without a lens adapter. The drawings in Section 

3

 show a Board

Level camera equipped with a lens mount adapter and one without a lens mount adapter. 

Standard cameras are always equipped with a lens adapter.

• Board Level cameras have two input ports and four output ports.

Standard cameras have four input port and four output ports.

• The type of connector and the pin assignments for the I/O port connector on Board Level

cameras are different from standard cameras. Section 

4

 provides detailed information for the

I/O connector and the pin assignments on Board Level cameras.

• The input ports and the output ports on Board Level cameras are not optoisolated. This

means that the electrical characteristics of the input ports and the output ports on Board
Level cameras are different from standard cameras. Sections 

6

 an

7

 describe the electrical

characteristics of the ports.

On standard cameras, optoisolators are used on the input and the output ports.

• An output reference voltage is supplied in the I/O connector on Board Level cameras. Sec-

tion 

8

 describes this reference voltage.

This reference voltage is not available on standard cameras.

• The timing for the Integrate Enabled signal on Board Level cameras is different from stan-

dard cameras. Section 

9

 shows the timing for Board Level cameras.

Caution!

The pin assignments and the electrical characteristics of the I/O ports on A600f 
Board Level cameras are different from standard A600f cameras. When using a 
Board Level camera, you must follow the guidelines in Sections 

4

6

, and 

7

. Failure 

to follow the guidelines will result in severe damage to the Board Level camera.

Содержание A600f

Страница 1: ...USER S MANUAL SUPPLEMENT Document Number DA00078802 Release Date 4 April 2006...

Страница 2: ...onably be expected to result in personal injury Basler cus tomers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Basler for any damag...

Страница 3: ...3 599 vc support europe baslerweb com Americas Basler Inc 740 Springdale Drive Suite 100 Exton PA 19341 U S A Tel 1 877 934 8472 Fax 1 877 934 7608 vc support usa baslerweb com Asia Basler Asia Pte Lt...

Страница 4: ......

Страница 5: ...nnector 5 4 1 I O Port Connector Location and Pin Numbering 5 4 2 I O Port Connector Pin Assignments 5 4 3 I O Port Connector Type 6 5 I O Port Schematic 7 6 Input Port Electrical Characteristics 8 7...

Страница 6: ...Contents II Basler A600f Board Level DRAFT...

Страница 7: ...d four output ports Standard cameras have four input port and four output ports The type of connector and the pin assignments for the I O port connector on Board Level cameras are different from stand...

Страница 8: ...ctromagnetic interference EMI characteristics of a camera no FCC or CE certification tests regarding EMI have been performed for Board Level cameras Users who design Board Level cameras into their pro...

Страница 9: ...Supplement Basler A600f Board Level 3 DRAFT Figure 1 Dimensions for A600f Board Level Cameras with a C mount Lens Adapter...

Страница 10: ...Supplement 4 Basler A600f Board Level DRAFT Figure 2 Dimensions for A600f Board Level Cameras without a C mount Lens Adapter...

Страница 11: ...e as shown in the table below Pin Designation Pin Designation 1 Output Port 0 6 Not Connected 2 Input Port 0 7 Output Port 3 3 Output Port 1 8 Not Connected 4 Input Port 1 9 Gnd 5 Output Port 2 10 5 V...

Страница 12: ...connector mounted on the camera board is a Hirose double row straight pin header part number DF20F 10DP 1V or the equivalent The connector is shown in Figure 4 The recommended mating connector is a H...

Страница 13: ...ment Basler A600f Board Level 7 DRAFT 5 I O Port Schematic The drawing below shows a basic schematic for the I O ports on A600f Board Level cameras Figure 5 I O Port Schematic for A600f Board Level Ca...

Страница 14: ...ical 0 An input voltage between 3 5 and 5 0 VDC indicates a logical 1 Typical current draw for the input port is 1 mA Figure 6 shows an example of a typical circuit you can use to input a signal into...

Страница 15: ...24 mA An output voltage between 4 2 and 5 0 VDC indicates a logical 1 The minimum high level output voltage i e 4 2 VDC will be present when the driver is sourcing the maximum allowed output current o...

Страница 16: ...han 10 nanoseconds The time between the end of exposure and the fall of IntEn signal will also be less than 10 nanoseconds This is considerably better than standard A600f cameras and is due to the dif...

Страница 17: ...History Basler A600f Board Level i DRAFT Revision History Doc ID Number Date Changes DA00078801 6 March 2006 Initial release of this document DA00078802 4 April 2006 Corrected the timing numbers in F...

Страница 18: ...Board Level DRAFT Feedback Your feedback will help us improve our documentation Please click the link below to access an online feedback form Your input will be greatly appreciated http www baslerweb...

Отзывы: