
Operation and Features
BASLER A102
k
3-5
DRAFT
Case 1 - Exposure Start With Frame Valid High
Figure 3-4: ExSync, Level-controlled Mode - Exposure Start with Frame Valid High
If the ExSync signal falls while frame valid is high as shown in Figure 3-4:
• The actual start of exposure can be up to 65 µs later than the fall of the ExSync signal.
(This is commonly referred to as an exposure start jitter.)
• Due to the jitter, you may find that the actual length of the exposure time decreases even
though you increase the length of the ExSync signal low time, or that the exposure time
increases even though you reduce the length of the ExSync signal low time.
• The actual length of the exposure time will be equal to the ExSync signal low time plus /
minus the jitter time.
L
As shown in Figure 3-4, FVAL
must
be low for at least 1 µs before the ExSync signal
rises.
Timing
charts are
not drawn to
scale.
Содержание A102K
Страница 4: ......
Страница 16: ...Introduction 1 8 BASLER A102k DRAFT...
Страница 36: ...Camera Interface 2 20 BASLER A102k DRAFT...
Страница 38: ...Operation and Features 3 2 BASLER A102k DRAFT Figure 3 1 A102k Sensor Architecture...
Страница 112: ...Configuring the Camera 4 34 BASLER A102k DRAFT...
Страница 118: ...Mechanical Considerations 5 6 BASLER A102k DRAFT...
Страница 130: ...Feedback iv BASLER A102k DRAFT...