Specifications 

12 

Input 
 
Outputs: 

Electromechanical relay 
SSR 
MOS gate 
Output for external SSR 
- K1 
- K2 

Power Supply 
 

 
Excitation Voltage (Vaux) 

 
Consumption 
Measurement Error

 

 

Temperature Drift 
Ambient Temperature / Humidity 
Protection Class: front / terminals 

 programmable,  
 on request (see device label) 

up to 2 
5A/250VAC with NO/NC contact 
1A/250VAC 
0.1A/60V, optically isolated  
5...24 VDC, 30 mA  

 relay,   SSR,   MOS gate,   for ext. SSR 
 relay,   SSR,   MOS gate,   for ext. SSR 
 230 VAC,       

 

 90…250 V,   

 24 VDC,         

 

 12...24 V,  

 ............................................. 
 10...30 V, 30 mA,   5 VDC, 10 mA, stabilized, 

 ............................................. 

less than 10 VA 

 

±

 0.3% from span 

 

±

 0,02% from span for 1 °C 

-10…65 °C / 0…85% RH, non-condensing 

 IP65,  

 

 IP54 / IP20  

 

 
 

Warranty and Support 

 

 

…………………………. 

           serial number 

 

…………………………. 

      manufacturing date

 

 

QC check mark …….……(passed)

(stamp) 

BASI Instrument AB

 

P.O.Box 

53

 

P

SE-275 06 VOLLSJÖ.. SWEDEN

 

tel: +

46 40 88009

 

fax: +

46 40 929877

 

E

-mail: 

sales

@

basi.se

      

 

QD-8.2.4-WC

 

 
 
 
 
 
 

 

Warranty

 

BASI

 warrants this product  

to be free from defects in materials  
and workmanship for 2 years. If your unit 
is found to be defective within that time,  
we will promptly repair or replace it.  
This warranty does not cover accidental 
damage, wear or tear, or consequential  
or incidental loss. This warranty 
does not cover any defects caused  
by wrong transportation, storage, installation, 
or operating (see '

Specifications

').  

Technical support

 

In the unlikely event that you encounter  
a problem with your 

BASI

 device, 

please call your local dealer or contact 
directly our support team. 

 

Содержание BBI250

Страница 1: ...LSJ tel 46 40 88009 fax 46 40 929877 E mail sales basi se www basi se BBI250 OPERATION MANUAL Please read this Operation Manual before mounting and operating Save the Manual for future references PROG...

Страница 2: ...provided when relay contacts are open Small AC current 1 5 mA at 230 VAC may still flow through the RC circuit All signal wires must be shielded They must not be packaged together with power cables Ne...

Страница 3: ...ould be powered ONLY by external source Output wiring Connect the outputs with regard to their types see Specifications via the respective terminals Power supply wiring Connect the right power supply...

Страница 4: ...l action direction of output K1 Differential 1 e1 Relay switching differential over set point for output K1 Differential 1 me1 Relay switching differential under set point for output K1 Time On 1 ym1...

Страница 5: ...ath the pointer light together with it dot only the pointer lights coo hEA cooling activates over set point heating activates under set point 0 999 ISU less than high range limit Set Point 1 0 999 ISU...

Страница 6: ...tively or Confirm the adjusted value by pressing simultaneously or If the new value has not been confirmed and no key has been pressed for a certain period of time value adjustment automatically cease...

Страница 7: ...be entirely displayed the unit generates blinking overflow messages oL or oL depending on PV sign If PV is out of the bargraph programmed range the corresponding endmost LED of the bargraph blinks If...

Страница 8: ...en pressed for a while the device automatically returns to Basic level storing all confirmed changes For quick exiting and saving use key combination or Output Control Alarm output operation The alarm...

Страница 9: ...L h W11 W21 ym1 ym2 out of range W12 W22 y 1 y 2 out of range W13 W23 km1 km2 out of range W14 W24 k 1 k 2 out of range W15 W25 e1 e2 out of range W16 W26 me1 me2 out of range W17 W27 1 2 outside L h...

Страница 10: ...a normal signal It is possible only if the input signal has not been changed with more than the Gradient value for 4 subsequent samples If the device has not determined a normal signal for 20 subseque...

Страница 11: ...nts of Directives 2004 108 EC 2006 95 EC and 2011 65 EU Bengt Ste n CEO BASI Instrument AB Waste Disposal Do not dispose of electronic devices together with household waste material If disposed of wit...

Страница 12: ...IP65 IP54 IP20 Warranty and Support serial number manufacturing date QC check mark passed stamp BASI Instrument AB P O Box 53 PSE 275 06 VOLLSJ SWEDEN tel 46 40 88009 fax 46 40 929877 E mail sales bas...

Отзывы: