Installation / Assembly
dizzer® XL Series Modules for Open Platform
– Assembly Instructions 1.1(2019-01) E inge
Page 32 of 44
© inge GmbH
5.5
Installation of dizzer
®
XL Modules on Conventional Module Racks
NOTE
CAUTION, PROPERTY DAMAGE!
Sufficient stability and building-side attachment of the dizzer
®
XL
Series Modules must be guaranteed. The brackets must connect
the module to the module rack tightly, tension-free and vibration-
free.
NOTE
For proper installation of the dizzer
®
Modules on conventional
membrane racks, heed correct orientation of the module
connections.
The inge
®
Ultra S 250 coupling is subject to a torque specification
of 40 Nm. If the coupling is re-installed, this must be adhered to.
Step
Activity
Figure
1
Prepare the module
a)
Check the position of the module connections.
b)
Remove the protective caps on the connections