IFX-21 User Guide 

 

BASF 

Contact Information 

7/12/2019 

V004

 

2 of 22 

 

 

1. C

ONTACT 

I

NFORMATION

 

T

ECHNICAL

 

4011 SE International Way, Suite 604 

Portland, OR 97222 

Phone: (503) 794-4073 

Fax: (503) 794-5591 

P

URCHASING

 

46820 Fremont Blvd. 

Fremont, CA 94538 

Phone: (510) 490-2150 

Fax: (510) 252-1871 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Copyright© 2019 BASF Corporation. All rights reserved. 

EXACTUS

®

 and TemperaSure are registered trademarks of BASF Corporation. The data contained in this publication are 

based on our current knowledge and experience. In view of the many factors that may affect processing and application of 
our product, these data do not relieve processors from carrying out their own investigations and tests; neither do these 
data imply any guarantee of certain properties, nor the suitability of the product for a specific purpose. Any descriptions, 
drawings, photographs, data, proportions, weights, etc. given herein may change without prior information and do not 
constitute the agreed contractual quality of the product. It is the responsibility of the recipient of our products to ensure 
that any proprietary rights and existing laws and legislation are observed.  

Although all statements and information in this publication are believed to be accurate and reliable, they are presented 
gratis and for guidance only, and risks and liability for results obtained by use of the products or application of the 
suggestions described are assumed by the user. NO WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, 
INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE MADE 
REGARDING PRODUCTS DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH. Statements or 
suggestions concerning possible use of the products are made without representation or warranty that any such use is 
free of patent infringement and are not recommendations to infringe any patent. The user should not assume that toxicity 
data and safety measures are indicated or that other measures may not be required. ©2019 BASF Corporation. 

Содержание EXACTUS IFX-21

Страница 1: ...IFX 21 USER GUIDE INDUSTRIAL COMMUNICATIONS MODULE...

Страница 2: ...t prior information and do not constitute the agreed contractual quality of the product It is the responsibility of the recipient of our products to ensure that any proprietary rights and existing law...

Страница 3: ...ounting 6 Device Wiring 7 5 Device Operation and Setup 10 Overview of Connection Methods 10 Value Display and Indicating LEDs 11 Device Configuration 12 The Configuration Menu 13 Analog Output Operati...

Страница 4: ...NTIFICATION The IFX 21 features a Nameplate as seen in Figure 1 FIGURE 1 EXAMPLE NAMEPLATE 1 Manufacturer and Product ID 2 Order Code and Serial Number 3 Power supply and current consumption 4 Ambient...

Страница 5: ...l technical information about these ports 4 INSTALLATION AND COMMISSION SOFTWARE MINIMUM REQUIREMENTS Windows 7 8 1 and 10 compatible Windows 10 only for USB service port connection TemperaSure Versio...

Страница 6: ...ir and or radiation shielding should be installed to ensure ambient temperatures remain within device operational limits see Section 7 1 In choosing a mounting location note should be taken that the d...

Страница 7: ...available 4 4 2 TERMINAL BLOCKS The power analog output and Modbus terminals use detachable spring cage connector blocks To insert or release a wire push in the tab as shown in Figure 5 Pin out numbe...

Страница 8: ...of 22 4 4 3 WIRING DIAGRAMS The IFX 21 enclosure features a simplified wiring diagram for all permanent device connections FIGURE 7 DEVICE WIRING Additional terminal wiring information is provided in...

Страница 9: ...us TIA 485 A RS485 TABLE 1 EXPANDED DEVICE WIRING The IFX 21 is natively a passive analog device it will modulate incoming current but it provides no voltage If required the incoming power may be rout...

Страница 10: ...ry to receive temperature readings over various protocols In these examples 4 units are shown however the methodology would be the same for any number of units BASF recommends that only communication...

Страница 11: ...NG THE USB PORT VALUE DISPLAY AND INDICATING LEDS FIGURE 10 DEVICE DISPLAY 1 Process Temperature display 2 Error and power indicating LEDS During normal operation the IFX 21 will display the temperatu...

Страница 12: ...nd adjust the pyrometer supply voltage Analog output settings and advanced operation modes such as peak picking or variance mode must be configured within the Pyrometer Please see the EXACTUS Optical...

Страница 13: ...configured through the included TemperaSure software by selecting IFX Settings from the pyrometer channel menu 5 4 2 IFX 21 CONFIGURATION The IFX 21 has a configuration menu which allows the user to s...

Страница 14: ...o Yes No 1 8mA Analog Output malfunction or failure No Yes No 2 2mA Default Output Yes Yes 2 7mA Analog Output is NOT enabled in Pyrometer settings Yes No Failure signal mA Default 3 6mA Yes Yes Measu...

Страница 15: ...ere Not suitable for explosive or corrosive atmospheres TECHNICAL 7 2 1 1 ANALOG OUTPUT Absolute Accuracy 0 2 of reading 4 20mA Accuracy vs Ambient Temperature 15ppm C 4 20mA Connector Removable 4 pin...

Страница 16: ...assigned Isolation 2 0kV Exposed Ethernet Ports 23 Telnet Port for configuration 502 Modbus TCP Port Max Link Distance 100 meters 328 feet Port Type Switch 7 2 1 3 PYROMETER PORT Connector RJ45 Elect...

Страница 17: ...th pyrometer Isolation 700V Pin Assignments Pin 1 V Pin 2 V Pin 3 V Pin 4 V 7 2 1 5 MODBUS TIA 485 A RS485 Connector Removable 4 pin 5 00 5 08mm plug Electrical Protocol RS 485 Half Duplex Bit Protoco...

Страница 18: ...INSTRUCTIONS Symptom Cause Remedy Display inactive No power supply connected Check power supply of the device Power supply applied device is defective Device must be replaced No analog output Analog o...

Страница 19: ...device contains no user serviceable parts Devices returned to BASF must be shipped in protective packaging Use the Contacts listed in Section 1 for further instructions and to obtain an RMA number DIS...

Страница 20: ...4 20 of 22 10 APPENDIX 7 SEGMENT DISPLAY 10 1 1 ALPHABET 10 1 2 MESSAGES INIT Shows on power up until pyrometer probe is discovered NO PROBE Shows when pyrometer probe fails to connect or is disconnec...

Страница 21: ...S device has an 8 bit address All of the pyrometers are configured to respond to the MODBUS address 0x01 When using MODBUS TCP always leave the pyrometer address at 0x01 Use a unit ID UID of 1 in the...

Страница 22: ...ated and no other MODBUS device on the RS485 network may be assigned either of those addresses If a network has multiple IFX21 devices they must be addressed at least 2 slave addresses apart i e first...

Отзывы: