This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent
the technical status at the time of printing.
© Copyright 2016 by Conrad Electronic SE.
Maintenance and cleaning
The product does not require any maintenance and should never be disassembled for any
reason. Repair or maintenance work must be carried out by a specialist.
Switch off the ultrasonic cleaner and disconnect it from the mains voltage before cleaning or
maintenance. Disconnect the mains plug from the mains socket.
If dirty water is inside the water tank, pour it out (e.g., into the drain of a sink).
You can use a clean, dry, soft cloth for cleaning. Wipe the inside (water tank/cover) and the
housing dry.
Do not use aggressive chemical or scouring cleaning agents, as this may lead to discolouration
or changes in the material on the surface.
Do not submerge the ultrasonic cleaner in or under water! Never clean the ultrasonic
cleaner in a dish washer! This will destroy the device and void the warranty!
After the device has dried completely, store it in a clean, dry, well ventilated place out of the
reach of children.
Troubleshooting
No information is shown in the display
• Make sure that the ultrasonic cleaner is connected correctly to a mains socket. Directly after
connecting, the display must light up (“180” is shown as default setting for a cleaning duration
of 180 seconds).
Insufficient cleaning
• Dirt is too persistent or adheres too much to the object to be cleaned.
• For persistent dirt can, you can use an additional cleaning agent approved for ultrasonic
cleaners. Always observe their instructions for use or dosing and safety instructions.
• Too many objects were placed in the water tank of the ultrasonic cleaner. Reduce the number
of objects.
Disposal
The product must not be disposed of in household waste!
Please dispose of the product, when it is no longer of use, according to the current
statutory requirements.
Technical data
Operating voltage ........................................ 220 - 240 V/AC, 50/60 Hz
Power consumption ..................................... max. 50 W
Protection class ........................................... II
Fill capacity of the water tank ...................... 560 ml
Depending on the size or the volume of the object to be cleaned, the actual fill
capacity is lower. Never exceed the marking for the maximum fill level “----MAX” in
the water tank.
Ultrasound cleaning frequency .................... 42000 Hz
Ambient conditions ...................................... Tempe5 °C to +40 °C, air humidity <90%
relative, non-condensing
Dimensions (water tank) .............................. 150 x 130 x 50 mm (L x W x H)
Dimensions (device) .................................... 210 x 170 x 145 mm (L x W x H)
Weight ......................................................... 0.9 kg