5.1.5 Connection
DANGER! Electric shock hazard!
The device can cause injuries due to improper installation!
Before installation and connecting the local power grid
specification should be compared with that of the device
(see rating plate). Connect the device only in case of
compliance!
Connect the device to the electrical installation while following international, national
and local regulations.
Cross-section of the connection cable and the manner of securing the cooking station
at the place of installation is determined by the qualified electricians. The above
mentioned features depend on the power of the used devices and the length of the
connection cable.
The cooking station should be always protected > 32A using RCD 30mA.
Maximum connected load of the cooking station is 52A.
The exception to this rule is the use of socket outlets with safety contact. In such a
case 32A protections, using RCD 30mA, are sufficient. However, in such a case an
electrician needs to disconnect the CEE socket outlet in the fuse box.
If, however, the CEE socket outlet is used in such circumstances, overload will
trigger the initial fusing.
If CEE socket outlets are used, sockets with safety contact cannot be used at the
same time. In such a case it is again necessary to reduce the connected load of the
cooking station.
Protection embedded in the cooking station prevents overloading of individual socket
outlets of the device.