- 42 -
Make sure that the gas bottle does not move during the operation of the device and
that the access to the gas bottle’s valve is not blocked.
Turn all gas control knobs to
“O“
position
and close the gas bottle valve.
Connect the gas hose with the grill. Install the pressure regulator on the gas hose
and connect it to the gas bottle valve. During the installation follow the instructions
included in the Operating Manual of the pressure regulator.
Tightness test
DANGER!
Never perform the tightness test with use of open flame!
After connecting the gas bottle, check all connections for possible gas leaks.
Tightness test may be performed only outdoors.
Make sure that the gas bottle valve is closed. Use the soapsuds solution or an
appropriate spray for detecting leaks.
Prepare ca. 60 - 90 ml of the soap solution, by mixing 1 part of dishwashing liquid
with 3 parts of water.
Apply the soap solution on the gas connections. Finally connect the pressure to the
gas hose by opening the gas bottle valve. The connections are tight when there are
no bubbles on the soap.
In case of leaks check connections, retighten them, and repeat the tightness test as
described above.
Replacement of burner nozzles
The device is factory-prepared for operation with the gas type and pressure
specified on the rating plate.
When required, the device may be set to the gas pressure available in the
installation country with use of special burner nozzles included in the delivery.
Replacement of the burner nozzles must be realized by the qualified gas
systems installer!
The factory-installed nozzle must be replaced with the nozzle suitable for the gas
pressure available in the installation country. Data for the burner nozzles are
specified in table
“Classification of gas fuel and burner nozzles used in
different countries
”
on page 39.