- 39 -
5. Installation and operation
5.1 Installation
CAUTION!
All installation, connection, and maintenance works must be realized by the
qualified or authorized personnel only, fulfilling the following requirements:
a) authorization from our company;
b) authorization from the local gas supplier.
Moreover the following regulations must be followed:
1)
DVGW TRGI (technical regulations for the gas installations);
2)
TRF (technical regulations for the liquid gas);
Furthermore, the appropriate regulations of the Building Code and Commercial Law
as well as OHS regulations must be observed.
Classification of gas fuel and burner nozzles used in different countries
Country
Categories
Gas
pressure
Main burner
nozzle
Side burner
nozzle
BE-CH-CY-CZ-
ES-FR-GB-GR-
IE-IT-LT-LU-LV-
PT-SK-SI
I
3+
28-30 mbar
1.02 mm
0.92 mm
37 mbar
BG-CY-CZ-DK-
EE-FI-FR-HR-
HU-IS-IT-LT-LU-
MT-NL-NO-SE-
SI-SK- RO-TR
I
3B/P
30 mbar
1.02 mm
0.92 mm
PL
I
3B/P
37 mbar
0.97 mm
0.88 mm
AT-CH-CZ-DE-SK
I
3B/P
50 mbar
0.91 mm
0.82 mm