Installation and operation
14 / 22
A120799
EN
4. Now set the temperature and time with buttons on the control panel.
Functions of buttons / indicators / LED indicators
A
Indicator lights: heating / lighting /
timer
F
Settings value quick increase
button (temperature, time)
B
Temperature digital display
G
Settings value quick decrease
button (temperature, time,
thermal processing)
C
Temperature unit indicator lights
(°C / °F)
H
SET function button
D
Thermal processing time digital
display
I
Lighting button
E
Timer start button
J
Start/Stop button
Temperature Setting
The temperature may be set in the range of 50 °C
– 300 °C, with increments of 1°C.
The oven chamber heating time to 150 °C reaches approx. 8 minutes.
1. Press the SET function button.
Temperature digital display blinks.
2. Set the required temperature with the use of settings value increase or decrease
buttons.
3. To confirm, press the SET function button.
After setting the required temperature, the current oven chamber temperature will
be displayed in the temperature digital display. Thus, you may control the oven
chamber temperature.
After setting the temperature and pressing the SET function button, the appliance
automatically proceeds to thermal processing time settings and the counterpart
digital display blinks.