
- 40 -
„SOFT“ rapid cooling with time regulation
1. Insert the probe into the food product.
CAUTION!
Insert the internal product temperature probe into the food product to a maximum
depth of 2 – 3 cm.
2. Hold the button „cooling with time regulation”
. The display will show the current
internal product temperature. Press the button „cooling with time regulation”
and
hold until the display shows the word „SOFT“.
After 3 seconds the display will show in red the internal unit temperature during rapid
cooling (-5°). This value may be changed using the buttons marked
or
Confirm the value via the „cooling with time regulation” button
.
3. Set the desired cooling time using the buttons
or
, confirm by pressing the
button „cooling with time regulation”
.
4. Activate the cycle by pressing the START button
.
5. The rapid cooling cycle is finished when the time set for rapid cooling has lapsed.
6. The conservation phase begins automatically. During the conservation phase, the
internal unit temperature will be displayed in red.
During the rapid cooling cycle it is possible to view the internal unit temperature by
pressing the button „cooling with temperature regulation via probe for measuring internal
product temperature”
. The internal unit temperature will appear in green on the
display for 5 seconds.