- 32 -
Safety thermostat
The device is equipped with the
safety thermostat (overheating protection
). If the
device is accidentally switched on with too little or no water and boils empty or there
is a lime and scale build-up inside, the device will switch off automatically.
Disconnect the device from the power supply (pull the plug!) and wait for cooling
down. Empty the water tank.
Unscrew the cap from the RESET pin of the safety
thermostat at the bottom of the device and press it in.
Tighten the cap again.
Fill in the water tank with drinking water and start the
device as usual.
If necessary, descale the device according to the
instructions in the section “Descaling”.
If the overheating status continues and the device
does not work properly, contact the technical service.
Overflow protection
In case of lame and scale build-up in the
water tank, the automatic refill system may
react with delay and continue pouring water,
despite reaching the mark of maximum
filling level.
In such a case, the second pressure switch
with an overflow protection tube (A) should
switch the device off.
The device must be then disconnected from
the power supply (pull the plug!).
Leave the device to cool off and empty the
water tank.
Leave the device turned upside down and empty the overflow protection tube.
Make sure that the overflow protection tube (A) is fully emptied and dried before
starting the device again.
Descale the device according to the instructions in section “Descaling”.
Fill in the water tank with drinking water and start the device as usual.
RESET Pin