Pag. 32/55
(Table 6) BURNER FEATURES (NL - CAT.
II
2L3B/P
)
Gas Type
Normal
Capacity
[kW]
Reduced
Capacity
[kW]
Diam. Main
Injector
[1/100 mm]
By-pass
Diameter
[1/100 mm]
Pilot Injectors
[N°]
Air
Regulation
“x” [mm]
BRAISING PAN BURNER 1 UNIT
Liquid Gas LPG
(G30-G31)
19.00
-
110 x 4
-
30
Close
Natural Methane Gas
(G25)
19.00
-
190 x 4
-
51
Close
BRAISING PAN BURNER 1,5 UNIT
Liquid Gas LPG
(G30-G31)
28.00
-
110 x 6
-
30
Close
Natural Methane Gas
(G25)
28.00
-
190 x 6
-
51
Close
Table 7) BURNER FEATURES (SE, DK, FI - CAT.
II
2H3B/P
,
III
1ab2H3B/P
,
III
1a2H3B/P
)
Gas Type
Normal
Capacity
[kW]
Reduced
Capacity
[kW]
Diam. Main
Injector
[1/100 mm]
By-pass
Diameter
[1/100 mm]
Pilot Injectors
[N°]
Air
Regulation
“x” [mm]
BRAISING PAN BURNER 1 UNIT
Liquid Gas LPG
(G30-G31)
19.00
-
110 x 4
-
30
Close
Natural Methane Gas
(G20)
19.00
-
190 x 4
-
51
Close
Town Gas
(G110)
19.00
-
450 x 4
-
100
Close
Town Gas
(G120)
19.00
-
375 x 4
-
100
Close
BRAISING PAN BURNER 1,5 UNIT
Liquid Gas LPG
(G30-G31)
28.00
-
110 x 6
-
30
Close
Natural Methane Gas
(G20)
28.00
-
190 x 6
-
51
Close
Town Gas
(G110)
20.00
-
450 x 6
-
100
Close
Town Gas
(G120)
20.00
-
375 x 6
-
100
Close