Installation and operation
1043613
17 / 28
EN
Resetting to Other Type of Gas / Required Adjustments
The appliances are set to the following gas type/category:
I3B/P
– 50 mbar
1. Check the type of the supplied gas in the country of installation, and, if needed,
reset the appliance to the other gas type.
Tables 1 and 2 in section
'Technical Specifications'
provide, depending on the
country of installation:
– what gas types may be used to power the appliance;
– nozzles and settings for each gas type that is used.
The number provided in Table 2 for proper nozzles is pressed on nozzles' bodies.
2. To adjust the appliance to the gas type, with which it would be effectively
powered, perform the following activities:
– exchange main burner's nozzle
– execute air adjustment
Exchange of Main Burner Nozzle / Air Adjustment
a
Gas nozzle
b
Nut
c
Screw connection
d
Olive
e
90° tube
f
Air sleeve
g
Screw
Fig. 3
1. Turn the appliance upside down to access the burner.
2. Loosen the screw (g) (Fig. 2).
3. Remove the main burner's nozzle (a).
4. Install the nozzles suitable for a given type of gas.
Содержание 1043613