Possible Malfunctions
104304
23 / 30
EN
Malfunction
Alarm
Appliance Condition
Solution
Power supply
malfunction alarm
or no electric
supply
Appliance stops
Check electric connections and
power supply
Disconnection of alarm signal:
– touch the control key once to
silence the buzzer
– touch the control key once to
silence the buzzer if it is the
first minute of operation
– only two touches of the control
key if the first minute has
elapsed
Discharge pump
alarm
Clogged discharge
opening
Check the appliance for obstacles
in discharge route
Discharge pump
damaged
Replace the discharge pump
Too long a
defrosting process
alarm
Defrosting process takes
too long
Check filling with coolant
Capacitive sensor
alarm
Check electric power connection
Condenser cleaning
alarm
Appliance continues
operation
Clean air filter and condenser
Inverted
evaporator
–deposit
probe alarm
Appliance stops
Check wiring on the sensor's
PCB; replace the sensor's PCB if
needed
IR probe alarm
The appliance stops, IR
probe damaged
Check probe connection to PCB
Replace the damaged probe