Controller 

(Louver & Fan/GHK Mode) 

 

 

 

 

Operation Manual

 

 

 

 

 

 

 

 

 

 

BARTLETT

 

Instrument Co.

 

1032 Avenue H 

Fort Madison, IA  52627 

319-372-8366 

www.bartinst.com

Содержание ACLIMATEBOSSC

Страница 1: ...CLIMATEBOSS Controller Louver Fan GHK Mode Operation Manual BARTLETT Instrument Co 1032 Avenue H Fort Madison IA 52627 319 372 8366 www bartinst com ...

Страница 2: ...10 Vent C D Settings 10 Timer Mister 1 2 10 Dehumidify 11 Statistics 11 Settings 11 Configuration 12 Programming 14 Stages DIF DAY NIGHT 14 Outputs Heat 1 Cool 1 14 Date Time 15 Dehumidification Vent Cycle 15 Timer Mister Function 18 Timer Alarm for Shade Curtain Control 19 Curtain Vent Control 19 Overview 20 Options 20 Heat 3 Option Models H CH 21 Wind Rain Alarm Integration 21 Statistics 22 Over...

Страница 3: ...fter COOL 1 to allow louvers to open In two zone mode COOL 2 and COOL 4 will not activate for 30 seconds after COOL 1 and COOL 3 respectively Definitions First we need to define and understand some terms TERM MANUAL DEFINITION AND DESCRIPTION Output OUTPUT is a relay that corresponds to a particular function heat cool timer etc Target Temperature or Set Point The base temperature set for each stag...

Страница 4: ...only displays when Auxiliary options C or CH are enabled Press to change settings Current Stage Displays the controller s current stage DIF DAY or NITE Graph Button Press to view graph of the controller s outputs Alarm Status Only displays if there is an active alarm Press to clear Cool Outputs 1 4 Indicates current status for each cool output C1 C2 C3 and C4 respectively Press to make changes Fig...

Страница 5: ...ap to change settings Outside Weather Displays current temperature outside Tap to view status and settings of Wind Rain alarm if connected Timers Timer outputs used for lights irrigation or other equipment Tap to change settings More Button When pressed returns to the home screen detailed above Dehumidification Dehumidification Vent Cycle used to maintain proper humidity levels Tap to change Stati...

Страница 6: ...perature for each stage and 24hr period Helps with troubleshooting and graphical tracking Timer Mister output for lights or irrigation fogging Humidity probe input to trigger the dehumidification vent cycle or the humidify misting cycle Controller Operations Options Option C Adds Proportional Output for Curtain Vent Control The model ACLIMATEBOSSC has the standard features listed above plus time p...

Страница 7: ...ou to lower the temperature at night to save on heating Controller Operations Target Temperature The figure below explains the workings of the stages DIF DAY and NIGHT Figure 4 shows the controller programmed the DIF stage to start at 06 00 6 00 am the DAY stage at 09 00 9 00 am and the NITE stage for 17 00 5 00 pm The target temperatures for the DIF stage 50 F the DAY stage 70 F and the NITE stag...

Страница 8: ... to the target temperature for each output Controller Operations Output Temperature Using the information in Figure 4 Figure 5 if the time is 8 00 AM the operating stage is DIF and the target temperature is 50 F The output temperatures for each output are as follows Target Temperature Offset Output Temperature COOL 4 50 F 11 61 COOL 3 50 F 7 57 COOL 2 50 F 4 54 COOL 1 50 F 2 52 HEAT 1 50 F 1 49 HE...

Страница 9: ...liances but will also give a wider swing in temperature The hysteresis can be set to values of 1 2 or 3 through the menu options Using the output temperatures from Table 1 and a hysteresis setting of 1 the trip points for each output will be as follows all temperatures are in F Output Temperature Hysteresis ON OFF COOL 4 61 1 62 60 COOL 3 57 1 58 56 COOL 2 54 1 55 53 COOL 1 52 1 53 51 HEAT 1 49 1 ...

Страница 10: ...omes on based on their offset Each output has an offset or step temperature to be added to Cools or subtracted from Heats the set point to determine when each output will activate As the controller changes modes the Heats and Cools will activate at different temperatures based on the mode s DIF DAY or NITE set point See the Programming page 14 for more information Vent C D Settings All ClimateBoss...

Страница 11: ...ce the last reset Settings Zone 1 Low Alarm Used to set the temperature for Zone 1 low alarm Default 32 F Zone 1 High Alarm Used to set the temperature for Zone 1 high alarm Default 131 F Zone 2 Low Alarm Used to set the temperature for Zone 2 low alarm Default 32 F Only appears when the controller is set for 2 Zones Zone 2 High Alarm Used to set the temperature for Zone 2 high alarm Default 131 F...

Страница 12: ...is used in conjunction with the Headgrower mobile app for remote monitoring and control of the Climate Boss See the WiFi section for more information about firmware updates WiFi Set up Wi Fi for Firmware download and for remote control and monitoring from the Headgrower mobile app Requires subscription Enable Wi Fi Enable or disable the Wi Fi feature Disable turns Wi Fi capabilities off at all tim...

Страница 13: ...eparate sensor thermistor for controlling boilers or bench heat Option CH combines Option C Option H to add both a proportional Curtain Vent control and a 3rd Heat option Timer Alarm Shade The Timer and Alarm outputs can be used to run a shade or energy curtain The timer is used as the extend signal and the alarm is used as the retract signal See page 18 for more information Humidity Cal Used to e...

Страница 14: ...next screen then press save To edit a temperature follow the same steps except under the zone1 or zone2 column entering your desired temperature on the next screen You can see the timeline of your settings on the top of the screen a full 24 hour timeline starting at 0 00 Outputs Heat 1 Cool 1 To access your output settings either press Heat Cool Settings in the menu or press any of your output ind...

Страница 15: ...ubtracting your step value see Table 1 on page 8 Therefore you edit this value by changing the step value seen below SP To change your offset value press the green number in the SP row Enter your value in degrees It will automatically become a negative number if entered for a heat appliance and a positive number if entered for a cool Date Time It is important to remember that the ClimateBoss uses ...

Страница 16: ...ur high You can change it to use a custom value by pressing the checkbox next to set temperature and entering a value The limits can only be set between the values of 32 and 131 Stage Enable Choose what times of day DIF DAY and NITE that the cycle can be active in Only appears in Humidity mode Limits Set the low and high limits for when the dehumidify cycle can run Output Setup Choose what outputs...

Страница 17: ... are in Timed mode Press it to toggle between on and off If on the vent cycle will continue to activate at its start time every day If off the vent cycle will activate at its start time a single time but then once the cycle completes the mode will change to Off Stage Enable This option will only appear if you are in Humid mode It allows you to choose which times of day DIF DAY NIGHT the cycle can ...

Страница 18: ...nutes format The maximum entry is 23 hours and 59 minutes 23 59 Repeat To choose whether it will repeat the following day press the repeat box like seen in Figure 10 This will toggle between on and off If set to off the mode will return to the off state after the timer runs Manual Control Timers can also be manually started by pressing the green manual start button like seen in Figure 10 When a ti...

Страница 19: ...urtain opens and the run time will determine how long it stays open At the end of the timer the alarm will activate sending a message to CIS that you can ignore and closing your curtain shade Curtain Vent Control The Curtain Vent control option adds the ability to open a curtain roof vent or vent window in 5 proportional steps This includes a step size or a programmable number of degrees above the...

Страница 20: ...step before the curtain vent will open or close to the next setting Tap this box to enter a value between 1 and 9 minutes Open Time You ll need to manually measure the amount of time in seconds to manually run the vent from fully closed to fully open By tapping this box and entering a value between 200 and 9999 seconds you can tell the controller the time that is required for the curtain or vent t...

Страница 21: ...he mid right of the screen See figure 15 The Heat 3 output is currently active if the box surrounding Heat 3 is red Grey indicates inactivity Wind Rain Alarm Integration If your operation has both our PC software C I S and a Wind Rain alarm The ClimateBoss can look at the activity of the wind rain alarm through the computer software and react accordingly By taking information from C I S the Climat...

Страница 22: ...ller s home screen The ClimateBoss also tracks the run time of each of the outputs Heat 1 Heat 2 Cool 1 Cool 2 Cool 3 Cool 4 and Heat 3 H and CH versions The ClimateBoss will store the information until it is reset and will also display the number of days since the last reset To view run times press the Run Times button in the bottom right of the statistics screen To reset run times press the Rese...

Страница 23: ... set point see Stages page 13 during the next stage transition DIF DAY NIGHT Vent Cycle or Timer Manual Start The dehumidification vent cycle or a timer cycle can be manually started This allows you to program a cycle set it to off and run it only on a manual cycle For instructions on how to manually start one of these cycles see Page 15 for the vent cycle and Page 18 for the timer cycle Outputs E...

Страница 24: ...imum setting of 55 Minimum setting of 1 DAY target temperature 18 Maximum setting of 55 Minimum setting of 1 NITE target temperature 18 Maximum setting of 55 Minimum setting of 1 Hysteresis setting 1 Not changeable Alarm settings Low value 0 High value 55 Values of 1 through 55 accepted Converting the Fahrenheit settings to Celsius temperatures generates the values in this table Although the defau...

Страница 25: ...ON SETTING Temperature Speed Units Fahrenheit F mph CIS ID 1 On to Auto time 10 Heat Cool Delay 15 Hysteresis 1 cannot be changed Alarms both zones Low 32 F High 131 F Number of Zones 1 Thermistor Fail Mode HEAT TIMER DEFAULTS OPTION SETTING Start Time 12 00 Run Time 00 00 Repeat OFF DEHUMIDIFICATION VENT CYCLE DEFAULTS OPTION SETTING Start Time 19 00 Exhaust 1 00 00 Preheat 00 00 Exhaust 2 00 00 ...

Страница 26: ...red when the calibration code is requested below The calibration code is also located on the label inside the humidity sensor casing To change enter your calibration code go to Menu Configuration Humidity Cal On the screen with the number pad enter your 4 digit code and press SAVE If necessary you may need to fine tune the calibration code Changing the value by 5 will cause a 2 drop in humidity re...