11
RECALL PROGRAM
is used to recall a previously programmed firing profile.
Example: To recall user program #5, use the following:
Step
Press
Display
Comment
1
RECALL
PROG
Alternately flashing:
USEr & 1
The controller is ready to accept the desired user number.
2
5
5
Indicates the user program selected.
3
ENTER
Programming complete
Display is back to Idle
User program #5 has been selected. . The current temperature then
flashes in the display.
WRITE YOUR OWN CONE FIRE PROGRAM
Writing your own cone fire program combines the versatility of the Vary-Fire program and the
heat-work calculation of a cone fire program. It is a great way to get custom heating and cooling
rates and still have the controller do the heat-work calculation to get the correct cone bend
regardless of firing rate. The steps to write your own cone fire are the same as entering a Vary-Fire
program except when you are programming the top temperature press the CONE TABLE key and
enter the desired cone number then press ENTER. The cone number and cone temperature will be
displayed in the program review. The cone temperature can be entered into any segment so you
can also have cool down segments in the program.
Start the Firing
Press Start to begin the firing
The display will show -ON- then the current temperature. You will here
clicking when the relays cycle power to the elements to regulate the
temperature.