background image

Button 1:

1. pressed: effect 1 (normal colour change)
2. pressed: effect 5: „LSD“

Button 2:

1. pressed: effect 2 (Soft colour change)
2. pressed: effect 6: Fire  „Fire“

Button 3:

1. pressed: effect 3: „Blob“
2. pressed: effect 7: Lightnings  „Flash“

Button 4:

1. pressed: effect 4: User colour change
2. pressed: effect 8: „Burst“

Important: Shutdown: if any button is pressed longer than abt. 3 seconds, all modules are switched of,
any further button will start its assigned effects,

The DIP-Switches - Default-Effects

Some  settings  (i.e.  the  default  effect  after  reset  or  power  on)  can  be  preset  with  the  internal  DIP
switches. For this the case of the module must be opened (see attachment).

Important: Please do not touch any of the electronic components, because off the risk of damage by
electrostatic  discharge.  We  recommend  to  use  a  small  non-conductive  tool  to  change  the  DIP
switches.

The switches are separated in 3 groups (as imprinted):

DIP 1,2: These two switches control hold time for effects 1 snd 2 (colour changes):

DIP 1

DIP 2

Effect 1

Effect 2

Off

Off

5 sec.

30 sec.

(default)

On

Off

10 sec.

60 sec.

Off

On

30 sec.

120 sec.

On

On

90 sec.

180 sec.

DIP 3,4,5: These switches are for the default effect after reset or power on. 

DIP 3

DIP 4

DIP 5

Effect

Off

Off

Off

Effect 1: Standard colour change, colour transition time 2.5 seconds (default)

On

Off

Off

Effect 2: Slow colour change, colour transition time 10 seconds (default)

Off

On

Off

Effect 3: Randomly faded colours „Blob“

On

On

Off

Effect 4: User defined olour change (can by changed by PC software

Off

Off

On

Effect 5: Randomly changed colours„LSD“

On

Off

On

Effect 6: Simulation Fire „Fire“

Off

On

On

Effect 7: Simulation Lighnings („Flash“)

On

On

On

Effect 8: Randomly coloured flashes („Burst“)

DIP 6,7,8 determine the „Group“ of a module. Because the modules can be connected as a network, it
should be possible to send command only to a part of the network too. This is what we call a „Group“.
In  example  if  several  modules  are  used  for  a  pool  illumination  (ceiling,  walls  under-water),  these
modules could be separated into three groups. Now it possible to send command i.e. only to modules
on the ceiling. More information can be found in the following paragraph „A Pool Scenario“..

Another  important  use  of  the  Groups  is  the  starting  colour  for  the  preprogrammed  colour  changes
after power on or reset: To achieve impressive effects - even without using a network or PC software -
the Groups can be used. Seven different starting colours are available:

DIP 6

DIP 7

DIP 8

Group

Starting colour  Index of starting colours

Off

Off

Off

(none)

Red

1  (Default)

On

Off

Off

Group 1

Green

4

Off

On

Off

Group 2

Blue

7

Chromoflex - Manual  - English V1.07 

- www.barthelme.de

Rev. 02.07.2006

- 8 -

Содержание CHROMOFLEX I350

Страница 1: ...ng Chromoflex comes with several built in effects from calming colour change up to show effects External manual buttons DIP switches or a PC software can be used to control the modules Up to 30 module...

Страница 2: ...rs marking obligation Particularly in connection with optics also weak LEDs can become very dangerous Staring into LEDs can cause irreparable damage to the eye s retina Hence NEVER STARE INTO THE BEAM...

Страница 3: ...LEDs in series most high power LEDs for 350mA constant current require around 3 3 7 Volts depending on the colour type and manufacturerer Normally green and blue need the highest voltages the forward...

Страница 4: ...all potentiometer on the supply where the output voltage can be adjusted within several percent We recommend to select the lowest voltage where all the LEDs work at full brightness without disturbance...

Страница 5: ...e of the LED stripe Regarding any possible voltage drop please see the previous paragraph Cable lengths up to 5 Mtr are allowed Note We found LED stripes of 10 Volts 12 Volts and 24 Volts Note We also...

Страница 6: ...perated in a network This means each module can either send or receive data For this the connectors RS232 RX ond RS232 GND are required The precondition for network operation is that all modules of th...

Страница 7: ...s Colour transition time 10 seconds Effect 3 Randomly faded colours Blob Effect 4 User defined colour change can be changed by the Chromoflex Editor software for PC default is red green blue Effect 5...

Страница 8: ...1 Standard colour change colour transition time 2 5 seconds default On Off Off Effect 2 Slow colour change colour transition time 10 seconds default Off On Off Effect 3 Randomly faded colours Blob On...

Страница 9: ...tabele 1 Infrared Remote Control Installation For controlling one ore more modules connected as a network also the infrared control can be used Only one single module within a network should be equip...

Страница 10: ...mode is entered At first all modules are stopped so the current colour will remain With buttons 2 and 4 Right and Left the active colour can be set the active colour will blink while button 2 or 4 is...

Страница 11: ...n On On Ceiling That s really all to do Software 1 2 3 1 We offer the Chromoflex Editor for free download from our Internet site The software does contain additional documentation not covered by this...

Страница 12: ...plies and has considerable advantages compared to traditional systems The modulation frequency is in the range from 120 Hz up to max 240 Hz Patent pending Maximum cable inductance can be calculated as...

Страница 13: ...Attachment Module Pinout Chromoflex Manual English V1 07 www barthelme de Rev 02 07 2006 13...

Отзывы: