Proper use 

Intended purpose. 

The micropump is intended for pumping liquids with varying flow rates controlled by the electronics. The controllers 
are intended for operating the micropumps. Any other use of the micropump or controller unit is deemed improper.  

Do not make any modifications or extensions to the pump or controller without the prior written consent of the 
manufacturer. Such modifications may impair the safety of the unit and are prohibited! Bartels Mikrotechnik GmbH 
rejects any responsibility for damage to the unit caused by unauthorized modifications to the pump and risk and 
liability are automatically transferred to the operator. 

Misuse. 

The use of liquids, which may alone or in combination create explosive or otherwise health-endangering conditions 
(including vapors) is not permitted. 

Staff selection and qualification. 

All  work  in  connection  with  the  installation,  assembly,  commissioning/decommissioning,  disassembly,  operation, 
servicing, cleaning and repairing of the pump and the controller must be carried out by qualified, suitably trained 
and instructed personnel. Work on electrical components and assemblies must be carried out by personnel with the 
necessary qualifications and skills. 

About this operating manual. 

Warnings and important notes are clearly identified as such in the text. The relevant text sections feature a specific 
sign. However, this icon cannot replace the safety instructions. Therefore, carefully read all safety instructions in this 
manual.  Warnings and important notes in this text are highlighted as shown below, according to the severity of the 
damage that might result from non-compliance. 

 

 

DANGER

 

 

DANGER indicates a hazard with a high level of RISK THAT, if not avoided, will result in death or serious injury. 

 

 

 

Содержание mpSmart-Flowstop

Страница 1: ...1 Rev 1 1 02 2021 mpSmart Flowstop...

Страница 2: ...claration of conformity 3 Description of function 3 Proper use 4 Intended purpose 4 Misuse 4 Staff selection and qualification 4 About this operating manual 4 The flowstop controlled system mpSmart Fl...

Страница 3: ...compliant to the EU Low Voltage Directive 2014 35 EU Description of function The mpSmart Flowstop have been developed for the transport of liquids The controller has been developed for operating the m...

Страница 4: ...ns including vapors is not permitted Staff selection and qualification All work in connection with the installation assembly commissioning decommissioning disassembly operation servicing cleaning and...

Страница 5: ...ugh amplitude and frequency Pressure range Up to 1 bar1 input voltage 5V USB operating temperature 5 C bis 40 C material in contact with fluid PPSU FPM PPS Tygon Lifetime pump 5000 h self priming yes...

Страница 6: ...When the valve is open and allows air or water to pass through the LED lights up In the figure the green lines represent the fluid channel The arrows mark the flow direction For the wiring use the in...

Страница 7: ...ff In addition you are able to open and close the valve manually Another option is the Timer mode Ticking the Timer mode box expands the window and you are able to set a timing mode for the micropump...

Страница 8: ...Fax 49 231 47730 501 Visit our Website www bartels mikrotechnik de produkte downloads for further information on applications Tutorials and helpful answers to frequently asked questions can be found...

Отзывы: