Getting started with mpSmart-Flowstop  

The mpSmart-Flowstop includes 2 main components: 

A mp6 micropump and a valve SMV of the company Takasago. 

For the fluid channel, connect them as shown in the following figure. Use tubes with an inner diameter of 1.3 mm 
for mp6 micropump inputs and outputs and for the valve. The valve requires one tube on each side. When the valve 
is open and allows air or water to pass through, the LED lights up. In the figure the green lines represent the fluid 
channel. The arrows mark the flow direction. 

For the wiring, use the included cable to connect the mp6 micropump and valve to the Driver PCB and the USB cable 
to connect the Arduino on the Driver PCB with your PC. 

Software 

For the use of the mpSmart-Flowstop, the necessary application needs to be downloaded from the download section 
on our website: 

www.bartels-mikrotechnik.de

  

Executing the mpSmart-Flowstop App opens the following window. 

 

Содержание mpSmart-Flowstop

Страница 1: ...1 Rev 1 1 02 2021 mpSmart Flowstop...

Страница 2: ...claration of conformity 3 Description of function 3 Proper use 4 Intended purpose 4 Misuse 4 Staff selection and qualification 4 About this operating manual 4 The flowstop controlled system mpSmart Fl...

Страница 3: ...compliant to the EU Low Voltage Directive 2014 35 EU Description of function The mpSmart Flowstop have been developed for the transport of liquids The controller has been developed for operating the m...

Страница 4: ...ns including vapors is not permitted Staff selection and qualification All work in connection with the installation assembly commissioning decommissioning disassembly operation servicing cleaning and...

Страница 5: ...ugh amplitude and frequency Pressure range Up to 1 bar1 input voltage 5V USB operating temperature 5 C bis 40 C material in contact with fluid PPSU FPM PPS Tygon Lifetime pump 5000 h self priming yes...

Страница 6: ...When the valve is open and allows air or water to pass through the LED lights up In the figure the green lines represent the fluid channel The arrows mark the flow direction For the wiring use the in...

Страница 7: ...ff In addition you are able to open and close the valve manually Another option is the Timer mode Ticking the Timer mode box expands the window and you are able to set a timing mode for the micropump...

Страница 8: ...Fax 49 231 47730 501 Visit our Website www bartels mikrotechnik de produkte downloads for further information on applications Tutorials and helpful answers to frequently asked questions can be found...

Отзывы: