Getting started with mpSmart-Dosing 

The mpSmart-Dosing includes 3 main components: 

A mp6 micropump, a mp-damper and a SFL3S1300F flowrate sensor. 

 

For the fluid channel, connect them as shown in the following figure. Use tubes with an inner diameter 1.3 mm for 
mp6 micropump in- and outlets as well as for the mp-damper. The 

SLF3S-1300F 

requires tube connectors on both 

sides which are included in the mpSmart-Dosing (UP D-646; Swivel Barb Adapter, 1/16" ID Tubing). As for the tube 
lengths between mp6 micropump & mp-damper or mp-damper & 

SLF3S-1300F 

we recommend at least 50 mm. 

 

 

 

For the wiring, use the included cable to connect the mp6 micropump and 

SLF3S-1300F 

to the Driver PCB and the USB 

cable to connect the Arduino on the Driver PCB with your PC. 

 

 

 

 

Содержание mpSmart-Dosing

Страница 1: ...1 Rev 1 4 01 2021 Flow Controlled System mpSmart Dosing...

Страница 2: ...Declaration of conformity 3 Description of function 3 Proper use 4 Intended purpose 4 Misuse 4 Staff selection and qualification 4 About this operating manual 4 The flow controlled system mpSmart Dosi...

Страница 3: ...ompliant to the EU Low Voltage Directive 2014 35 EU Description of function The mpSmart Dosing have been developed for the transport of liquids The controller has been developed for operating the micr...

Страница 4: ...ns including vapors is not permitted Staff selection and qualification All work in connection with the installation assembly commissioning decommissioning disassembly operation servicing cleaning and...

Страница 5: ...hyb micropump Damper Flowmeter Sensirion SLF3S 1300F Tubing Tubing connectors Swivel Barb Adapter 1 16 ID Tubing Driver Board Software with GUI mp hc min Flowrate 0 5 ml min max Flowrate 8 ml min acc...

Страница 6: ...micropump in and outlets as well as for the mp damper The SLF3S 1300F requires tube connectors on both sides which are included in the mpSmart Dosing UP D 646 Swivel Barb Adapter 1 16 ID Tubing As fo...

Страница 7: ...ecognized and choose the right COM Port When selected click on Connect to start the communication between the program and the driver If the device was not found you might need to install the driver fo...

Страница 8: ...Rev 1 4 01 2021 Afterwards the mp6 micropump can be started or stopped with the on or off button The current flowrate is displayed underneath or as a time plot on the right of the Evaluation software...

Страница 9: ...mund Germany www bartels mikrotechnik de info bartels mikrotechnik de Tel 49 231 47730 500 Fax 49 231 47730 501 Visit our Website www bartels mikrotechnik de produkte downloads for further information...

Отзывы: