4

 

Rev. 1.2 (04.2020)   

 

         

 

Proper use 

Intended purpose 

The micropump is intended for pumping liquids or gases with varying flow rates controlled by the electronics. The 
controllers  are  intended  for  operating  the  micropumps.  Any  other  use  of  the  micropump  or  controller  unit  is 
deemed improper.  

Do not make any modifications or extensions to the pump or controller without the prior written consent of the 
manufacturer. Such modifications may impair the safety of the unit and are prohibited! Bartels Mikrotechnik GmbH 
rejects any responsibility for damage to the unit caused by unauthorized modifications to the pump and risk and 
liability are automatically transferred to the operator. 

Misuse 

The use of liquids, which may alone or in combination create explosive or otherwise health-endangering conditions 
(including vapors) is not permitted. 

Staff selection and qualification 

All  work  in  connection  with  the  installation,  assembly,  commissioning/decommissioning,  disassembly,  operation, 
servicing, cleaning and repairing of the pump and the controller must be carried out by qualified, suitably trained 
and instructed personnel. Work on electrical components and assemblies must be carried out by personnel with the 
necessary qualifications and skills. 

About this operating manual 

Warnings and important notes are clearly identified as such in the text. The relevant text sections feature a specific 
sign. However, this icon cannot replace the safety instructions. Therefore, carefully read all safety instructions in 
this manual.  Warnings and important notes in this text are highlighted as shown below, according to the severity 
of the damage that might result from non-compliance. 

 

 DANGER

 

 

Danger indicates a hazard with a high level of risk that, if not avoided, will 

result in death or serious injury. 

 

 

Содержание microComponents mp6-XOEM

Страница 1: ...1 Rev 1 2 04 2020 Operating Manual for Controller mp6 XOEM...

Страница 2: ...this operating manual 4 The mp6 XOEM controller 5 Technical specifications mp6 XOEM 5 Electrical Characteristics 6 Pin description 7 Connecting the micropump with the mp6 XOEM 8 Examples of circuiting...

Страница 3: ...ant to the EU Low Voltage Directive 2014 35 EU Description of functions The micropumps have been developed for the transport of gases or liquids The controllers have been developed for operating the m...

Страница 4: ...ditions including vapors is not permitted Staff selection and qualification All work in connection with the installation assembly commissioning decommissioning disassembly operation servicing cleaning...

Страница 5: ...w additional components or a microcontroller In order to locate Pin 1 please refer to the following figure The pin is marked with a colored spot or triangular marking on the corner of the PCB Technica...

Страница 6: ...LITUDE 0 5 1 3 VDC min voltage at pump Vpump AMPLITUDE 0 5 VDC 10 Vpp max voltage at pump 1 Vpump AMPLITUDE 1 25 VDC 250 260 270 Vpp Frequency output F VDD 5 V Default 200 Hz Digital Low Signal 0 V Di...

Страница 7: ...ut 0 Address inputs allow up to four connections on one common bus Connect A0 to GND or VDD 8 P1 Piezo actuator 1 positive electrode see page 9 9 P1 Piezo actuator 1 negative electrode see page 9 10 P...

Страница 8: ...d with the mp6 XOEM via a FCC connector More information concerning this connector and the pin layout of the micropump can be found in manual of the micropump mp6 series DANGER The output of the mp6 X...

Страница 9: ...amplitude to the micropump will be defined by external components The amplitude can be varied in the range from 0 Vpp to 250 Vpp Using a voltage divider it is possible to set the amplitude with only...

Страница 10: ...citor This can only be done my supplying a clock signal to the CLK pin witch is shown in the next chapter Operation with variable settings via microcontroller Using a microcontroller to operate the mi...

Страница 11: ...f the mp6 QuadOEM on our download page To activate the I C Interface the onboard processor has to be deactivated by tying the reset pin to Ground Select a desired slave address connecting pins A0 and...

Страница 12: ...l 49 231 47730 500 Fax 49 231 47730 501 Visit our Website www bartels mikrotechnik de for further information on applications Tutorials and helpful answers to frequently asked questions can be found i...

Отзывы: