21-56N0-7N0001/392164
Reservation
Technical data subject to change without notice.
No claims for damages arising from alternations, errors or misprints shall be allowed.
Page 7 / 20
Installation of the end seal
Cut the trace heater off straight.
Remove 3/4″ (20 mm) of the outer jacket.
Remove the exposed grounding braid. Make sure that the
insulation jacket is not damaged.
Cut in a triangle (1/4″ / 5 mm) between the bus wires.
CAUTION
The silicone adhesive may cause irritation to skin and eyes. Avoid
eye contact. Avoid repeated or prolonged skin contact. In case of
contact with eyes, rinse with water and seek medical advice.
Put silicone adhesive onto the exposed insulating jacket and into the
end cap.
Push the end cap over the end of the trace heater.
NOTICE
Allow the adhesive to cure for 20 minutes, then visually inspect. Full
strength is reached after 24 hours.
10
14
13
12
11