Operational Instruction (Translation) / EN
2
Note on instructions
When working in hazardous areas, the safety of personnel and
equipment depends on compliance with the relevant safety
regulations. The people in charge of installation and maintenance
bear a special responsibility. It is essential that they have an exact
knowledge of the applicable rules and regulations.
The instructions provide a summary of the most important safety
measures and must be read by everyone working with the product
so that they will be familiar with the correct handling of the
product.
The instructions have to be kept for future reference and must be
available throughout the expected life of the product.
Description
ComEx is a flexible system that offers both standardized and also
customized local control and display stations.
The standard enclosures, single (07-3511-…/07-3514-…), double
(07-3512-…/07-3515-…) and triple (07-3513-…/07-3516-…)
can be combined with various actuators, switching modules, and
luminous modules.
ComEx Control and Indicating Devices
Typ 07-351*-**************
Explosion protection
ATEX
Ex type of protection
Ex II 2 G Ex db eb IIC T6 Gb
Ex II 2 G Ex db eb ia IIC T6 Gb
Ex II 2 D Ex tb IIIC T80 °C Db
-55 °C
≤
Ta
≤
+60 °C
0044
Certification
CML 14 ATEX 3073X
IECEx
Ex type of protection
Ex db eb IIC T6 Gb
Ex db eb ia IIC T6 Gb
Ex tb IIIC T80 °C Db
-55 °C
≤
Ta
≤
+60 °C
Certification
IECEx CML14.0029X
Ambient temperature
range
-55 °C to +60 °C
(-67 °F to +140 °F)
Approved for zones
1, 2 and 21, 22
Applicable Documents
– Certificates
– Operation instructions of the installed
components
– Delivery note
(includes a list of installed components)
The retention and observation of these
documents is mandatory.
If limited components are used, the information
of the correct usage can be found on shipping
documents and related certificates.
Technical data
Protection class
Up to IP66/IP67 (IEC 60529)
Rated insulation voltage
Max. AC 690 V
Rated current
Max. 16 A
Intrinsically safety
parameters
Only for intrinsically safe devices:
Input voltage (U
i
):
30 V
Input current (I
i
):
150 mA
Input Power (P
i
):
1 W
Inductance (L
i
): negligible
Capacitance (C
i
): negligible
Connection type
Terminals, 2.5 mm²
Torque: 0.4 Nm (0.3 lb.ft)
PE conductor terminals
4 x 2.5 mm²
Torque: 0.4 Nm (0.3 lb.ft)
Cable entry
Standard version:
– M20 x 1.5 for cable with Ø 7 to 13 mm
(0.27 to 0.51 in)
Special version:
– M20 x 1.5 for cable with Ø 11 to 14 mm
(0.43 to 0.55 in)
– M25 x 1.5 for cable with Ø 12 to 17 mm
(0.47 to 0.67 in)
– M25 x 1,5 for cable with Ø 14 to 18 mm
(0.55 to 0.71 in)
Enclosure material
Plastic (thermoplastic)
Enclosure Screws
M4 x 30
Torque: 0.7 Nm - 1.2 Nm (0.5 - 0.8 lb.ft)
Potential equalisation,
external
M6
Torque: 3 Nm (2.2 lb.ft)
Dimensions
See page 3.
01-3511-7D0002-A-05/2020-ESS-409352