102
Troubleshooting
CFPP Process Analyzer CFPP-4.2 03/2016
In case of a malfunction, first check if the PACS process software shows any error
messages. In the software manual, you will find a list of error messages, possible causes
and suggested solutions.
If the process software does not display any error messages, the following list helps you to
identify the problem and its possible causes.
If you are unable to solve the problem, we will be pleased to help you:
BARTEC BENKE GmbH
Borsigstraße 10
21465 Reinbek/Hamburg
Germany
Tel.:
+49 (0) 40 -72703 0
Fax:
+49 (0) 40 -72703 363
E-Mail: [email protected]
Error
Possible cause
Troubleshooting
Analyzer is switched off /
does not start
a) Display of overpressure
control is not present
Power supply of the analyzer
is interrupted (e.g. broken or
blown fuse)
Check and restore power
supply
Fusing of overpressure
control system is faulty.
Remove the cause of the
malfunction.
Analyzer is switched off /
does not start
a) Display of overpressure
control is present
Overpressure control system
has switched off the analyzer
/ cannot start the analyzer
Please refer to operating
manual of the overpressure
control system.
Internal fuses are faulty /
blown
Remove the cause of the
malfunction.
Power supply of the
I/O board interrupted or
I/O board faulty
Remove the cause of the
malfunction.
Instrument air supply is
interrupted
Remove the cause of the
malfunction.
No Ready signal /
measuring result over a
longer period of time
Analyzer is switched off.
see above
PACS is in “Standby” or
“Shutdown” state; or PACS is
not operating;
Please refer to the software
manual.
Unsuitable parameter settings Adjust the parameters (see
software manual).
Cable connection to the
analyzer is interrupted
Remove the cause of the
malfunction.
Measuring value output
signals an unusual or
Sudden significant changes in
product properties
Содержание CFPP-4.2
Страница 1: ...CFPP Process Analyzer CFPP 4 2 Operating Instructions 395778MDHEN A 03 2016 ...
Страница 6: ...IV Contents CFPP Process Analyzer CFPP 4 2 03 2016 ...
Страница 7: ...General 5 03 2016 CFPP Process Analyzer CFPP 4 2 1 General ...
Страница 9: ...Safety 7 03 2016 CFPP Process Analyzer CFPP 4 2 2 Safety ...
Страница 25: ...Introduction 23 03 2016 CFPP Process Analyzer CFPP 4 2 3 Introduction ...
Страница 28: ...26 Introduction CFPP Process Analyzer CFPP 4 2 03 2016 ...
Страница 29: ...Technical Data 27 03 2016 CFPP Process Analyzer CFPP 4 2 4 Technical Data ...
Страница 33: ...Analyzer Description 31 03 2016 CFPP Process Analyzer CFPP 4 2 5 Analyzer Description ...
Страница 43: ...Transport Packaging and Storage 41 03 2016 CFPP Process Analyzer CFPP 4 2 6 Transport Packaging and Storage ...
Страница 46: ...44 Transport Packaging and Storage CFPP Process Analyzer CFPP 4 2 03 2016 ...
Страница 47: ...Installation and Disassembly 45 03 2016 CFPP Process Analyzer CFPP 4 2 7 Installation and Disassembly ...
Страница 55: ...Initial Operation 53 03 2016 CFPP Process Analyzer CFPP 4 2 8 Initial Operation ...
Страница 64: ...62 Initial Operation CFPP Process Analyzer CFPP 4 2 03 2016 ...
Страница 65: ...Operation 63 03 2016 CFPP Process Analyzer CFPP 4 2 9 Operation ...
Страница 69: ...Maintenance 67 03 2016 CFPP Process Analyzer CFPP 4 2 10 Maintenance ...
Страница 102: ...100 Maintenance CFPP Process Analyzer CFPP 4 2 03 2016 ...
Страница 103: ...Troubleshooting 101 03 2016 CFPP Process Analyzer CFPP 4 2 11 Troubleshooting ...
Страница 107: ...Troubleshooting 105 03 2016 CFPP Process Analyzer CFPP 4 2 ...