![Barrett BH8 Series Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/barrett/bh8-series/bh8-series_user-manual_475712056.webp)
BH8-Series – User’s Manual
www.barrett.com
© 2007 Barrett Technology®, Inc.
Document: D3000, Version: AF.00
Page 54 of 82
Symptom:
The TorqueSwitch™ does not breakaway properly, prohibiting the fingertip
from completing a form grasp around an object.
Possible Solution:
1.
The close velocity is too slow. Increase the close velocity greater than or equal to 40.
2.
Reinitialize the finger; this may reset the TorqueSwitch™.
3.
If the BarrettHand™ has been inactive for an extended period or if the finger has been
slammed open against its stop with a high velocity setting, the TorqueSwitch™ may need to
be manually activated. Insert a 2-mm hex wrench into the left Drive Access hole, as shown
in Figure 20. Rotate counterclockwise to open the finger fully. Next, press very hard against
the inner link to constrain it from moving while not constraining the outer link, as the person’s
thumb is doing in Figure 19, while torqueing the hex wrench clockwise. Increase torque until
the fingertip breaks free, so that it can be rotated easily while the inner link remains
stationary. Remove the 2-mm hex wrench and reinitialize the finger.
4.
If the problem persists, contact Barrett Technology.
Figure 19 - Manual Torque Switch Activation