Bring Finger
toward Motor Face
Engage
teeth
Create gap,
then clamp
finger down
Figure 15 - Reattaching Fingers after Maintenance
9.
Insert and tighten the finger attachment shoulder screw to retain the finger in place, as shown
in Figure 12. Check the connection to the motor housing to be sure all gaps are closed.
7.4 Strain Gages
Due to variations in materials, manufacturing and external forces, the strain gage values may
change. These changes will affect the zero force reading for each beam differently. To maintain
consistent results, the zero force reading needs to remain constant. Each strain gage is equipped
with a balancing potentiometer. Adjusting the balancing potentiometer will change the strain gage
output for that finger. Adjust the balancing potentiometer until the no-load value is between 100
and 140. Use the following steps to zero the strain gages:
1.
Initialize the BarrettHand™.
2.
Terminate the spread motor so it can be moved around the palm. (Issue the "T" command)
3.
Remove the Shroud Cover screws shown in Figure 16. Some models of the BarrettHand™
will have four Shroud Cover screws. Remove the Shroud from the finger link.