Accessories

Rigid Stainless-Steel Probes

Probes fit traditional apparatus and glassware
without modifications. Their rigid 316
Stainless-steel sheaths are .25”(6.4 mm) in
diameter, roughly the same as traditional
glass thermometers. Available with or without
Teflon coating, all have 6’ (183 cm) lead
wires.

GLASS-PROBE™ Quartz Glass

Probes

Electrothermal’s patented GLASS-PROBE is
highly resistant to most chemicals and ther-
mal shock. Sheath is the same diameter as
standard laboratory thermometers, .25” (6.4
mm) so it is compatible with common ther-
mometer adapters, clamps and apparatus.
The glossy quartz sheath may be cleaned
more thoroughly than metals, Teflon or other
glasses. Usable up to 500°C. Each thermo-
couple is individually tested and permanently
marked with a serial number for identification.

Bendable Stainless-Steel Probes

Probes have bendable 316 stainless-steel
sheaths that are 1.6 mm diameter. They may
be used straight or gently bent to suit your
application. Probe has connector that plugs
into extension cord.

Thermocouple Extension Cords

These extensions are made from appropriate
thermocouple wire to minimize their effect on
readings. Straight extension cords are 130 cm

9

Parts List

Содержание SET-TEMP limit

Страница 1: ...SET TEMP limit OPERATING INSTRUCTIONS 1 BARNSTEAD THERMOLYNE CORPORATION LT1153X2 6 24 99...

Страница 2: ...of Operation 5 Installation 6 Temperature Probe Connection and Placement 6 Connecting your Heater and Other Temperature Controls 6 Operation 7 Maintenance and Servicing 8 Replacing Fuses 8 General CL...

Страница 3: ...ting tapes hot plates ovens baths and other general heat ing equipment General Usage Do not use this product for anything other than its intended usage Warnings To avoid personal injury 1 Refer servic...

Страница 4: ...heaters up to 1800 watts 100 120 VAC Shipping weight 4 4 lb 2 kg Selected probe will dictate actual temperature range within range specified 4 General Specifications Environmental Conditions Operatin...

Страница 5: ...off power to laboratory heaters to guard against thermal runaway when the temperature sensed by a thermo couple exceeds the dial setting Heating will not resume until the RESET key is pressed 5 Princ...

Страница 6: ...ood idea to have the tip of the probe resting on the inside bottom of the flask Then should the liquid boil away the sensing probe will still be effectively heated by the man tle and SET TEMP LIMIT wi...

Страница 7: ...ure scale is in degrees C and degrees F 3 Press the reset key to energize SET TEMP LIMIT s receptacle Note that each time SET TEMP LIMIT looses power or is turned off the RESET key must be pressed to...

Страница 8: ...fuse A 0 5 Amp 5x20mm fast acting fuse protects the unit s low power electronics If this fuse blows use a slot ted screwdriver to remove the old fuse and install a new 0 5 Amp fast acting fuse General...

Страница 9: ...mm so it is compatible with common ther mometer adapters clamps and apparatus The glossy quartz sheath may be cleaned more thoroughly than metals Teflon or other glasses Usable up to 500 C Each therm...

Страница 10: ...ROBE 1 4 diameter x 12 long Type J Thermocouple 8005 GLASS PROBE 1 4 diameter x 18 long Type K Thermocouple 8007 GLASS PROBE 1 4 diameter x 24 long Type K Thermocouple 8403 Bendable s s probe 1 16 dia...

Страница 11: ...whom you purchased this unit or can be obtained promptly from the factory When service or replacement parts are needed we ask that you check first with your dealer If the dealer cannot handle your re...

Страница 12: ...wn discre tion Heating elements however because of their susceptibility to overheating and contam ination must be returned to our factory and if upon inspection it is concluded that failure is not due...

Отзывы: