Carbon Filter Installation
Chlorine can also damage your membranes, resulting in
premature membrane failure. Therefore, your DIamond
RO uses an extruded carbon filter to remove chlorine from
your feed water.
Install the carbon filter as follows:
1.
Remove the carbon filter (Part Number D502115)
from its packaging and wet the o-rings with
water.
2.
Insert the carbon filter straight into the right posi-
tion upper and lower quick disconnect and push
until firmly connected. For easier installation,
connect bottom first.
Membrane Installation
12 LITER PER HOUR UNITS (1 MEMBRANE)
1.
Remove the RO membrane from its packaging.
Note the location of the FEED, PRODUCT, and
REJECT connections on the housing. The cor-
rect orientation for the installed membrane will be
vertical with the FEED connection down.
2.
Open the left side door on the DIamond RO.
3.
Locate the three unconnected tubes labeled
FEED, PRODUCT, and REJECT. Refer to tubing
installation and mark tubing 1.75 cm (11/16”) from
end.
4.
Note the orientation of the membrane housing
and install the unconnected tubes into the corre-
sponding connectors on the membrane housing.
To do so, first wet the tube end with water and
push the tube end firmly into the connector. Start
with the FEED followed by the PRODUCT and
finally the REJECT.
5.
Note the orientation of the membrane housing
and press the housing into the two holding clips.
6.
The door can remain open until the unit has been
operating and you checked for possible water
leaks at the membrane connections.