background image

 
 
 
 

 

 

 

Installation & Operation Manual 

 
 
 
 
 
 

January 2011 
Rev. 2.0 
 

 
 
 
 

 

215, 7710 5

th

 St. S.E.  

Phone: (403) 255-9544 

Calgary, Alberta, Canada  

Fax: (403) 259-2343 

T2H 2L9  

www.barnett-engg.com 

 

e-mail: [email protected] 

Содержание ProTalk Cv3

Страница 1: ...Installation Operation Manual January 2011 Rev 2 0 215 7710 5th St S E Phone 403 255 9544 Calgary Alberta Canada Fax 403 259 2343 T2H 2L9 www barnett engg com e mail sales barnett engg com...

Страница 2: ......

Страница 3: ...TS 5 WIRING YOUR OUTPUTS 7 5 PROGRAMMING 8 PROGRAMMING WITH A PC 8 PROGRAMMING WITH A HANDSET 9 HANDSET PROGRAMMING CODES 10 6 TESTING THE INSTALLATION 31 7 OPERATIONS 32 8 SPECIFICATIONS 37 9 TECHNIC...

Страница 4: ......

Страница 5: ...g a remote telephone for control of external equipment Configuration of the ProTalk Cv3 can be accomplished using the dedicated PC application using a local programming telephone or by remotely callin...

Страница 6: ...or Mobile Directory Number MDN Additionally to program the Cv3 and the embedded transceiver one of the following is required Standard telephone set with DTMF keypad or Personal Computer with CD Drive...

Страница 7: ...internal battery charger operates with input voltages between 8 and 30 volts DC The internal battery is limited to 1 4Ahr if you require a larger battery capacity please contact our sales office for...

Страница 8: ...sales office if your needs exceed the limits of this antenna as we may be able to supply or recommend an appropriate substitute Installation using a two way radio or public address system The radio po...

Страница 9: ...e or terminal for inputs 7 through 10 Technical drawings have been provided on page 41 for your reference In addition to the standard detection of an alarm state at the input a digitally formatted inp...

Страница 10: ...s DC and 0 to 30 volts DC For analog voltage operation connect the signal to the single terminal for inputs 1 through 6 and either the or terminal for inputs 7 through 10 Inputs 7 through 10 are also...

Страница 11: ...an be programmed as new alarm present any alarm present a pulsed output when an acknowledgement is received or as a system alarm When used for status indicators specific relays are assigned as follows...

Страница 12: ...ill ask you if you want Windows Update to search for software select No not at this time You will then be prompted for an installation CD This is the software that was provided to you and should still...

Страница 13: ...Programming For a remote session call in to the B1277 from your TouchTone telephone set When answering an incoming call this unit responds depending on the previously programmed Security Level setting...

Страница 14: ...five seconds the Cv3 will announce the menu choices Voices page 11 Directories page 12 General Site Configuration page 14 Input Configuration page 16 Output Configuration page 22 Group and Shift Conf...

Страница 15: ...oices Exit to Main Menu Exit to Main Menu Playback or Record Voices Cv3 Site is Ajax Compressor Station or Input 1 is Low Temperature or Output 1 is Yard Lights You Record new voice Exit to voice menu...

Страница 16: ...to the command list that follows for the available directory entries Cv3 Directory Group 1 Shift 1 Line 1 is or Directory Line 1 is DIAL 2559544 VOICE You Edit current line Erase current line Insert l...

Страница 17: ...llowing Quick Commands DIAL VOICE is the telephone number RADIO ALERT VOICE WAIT is the time in seconds 255 SMS TEXT is the data phone number Custom Sequences Custom sequences are created by selecting...

Страница 18: ...0 off 1 30 min 2 60 min 3 120 min 4 240 min Exit to Main Menu Next setting Cv3 Relay voices are You Enter new value 0 off 1 on Exit to Main Menu Next setting Cv3 Security Level is You Enter new value...

Страница 19: ...gits hours 01 02 04 06 08 or 012 hours 1 to 7 digits days 1 Monday 2 Tuesday Exit to Main Menu Next setting Cv3 Auto Report Radio is You Enter new value 0 off 1 on Exit to Main Menu Next setting Cv3 A...

Страница 20: ...input 7 5 volt analog input 8 30 volt analog input 9 Current input 10 System Acknowledge input 11 System Shift select input Exit to Main Menu Next setting for this input Menu items for Digital Inputs...

Страница 21: ...Main Menu Next setting Cv3 Input Level is You Enter new value 1 normally high or transition to low 2 normally low or transition to high 3 either transition Exit to Main Menu Next setting Cv3 Time Scal...

Страница 22: ...e 1 seconds 2 minutes Exit to Main Menu Next setting Menu items for Totalizer Inputs are Cv3 Input N Is You Enter new value 0 disabled 1 enabled 1 to 6 new group member Exit to Main Menu Next setting...

Страница 23: ...ue 0 disabled 1 enabled 1 to 6 new group member Exit to Main Menu Next setting Cv3 Input Level is You Enter new value 1 normally high or transition to low 2 normally low or transition to high 3 either...

Страница 24: ...enu Next setting Cv3 Input Level is You Enter new value 1 normally high or transition to low 2 normally low or transition to high 3 either transition Exit to Main Menu Next setting Cv3 Timeout Interva...

Страница 25: ...A high setpoint must be within the Decimal Minimum and Maximum and must not be less than the Low Setpoint Hysteresis value Exit to Main Menu Next setting Cv3 Setpoint Low is You Enter new value Enter...

Страница 26: ...for this input Menu items for Manual On Off Outputs are Cv3 Output One Type is On Off Cv3 Output Format is You Enter a new value 0 NO contacts 1 NC contacts Exit to Main Menu Next setting Cv3 DTMF On...

Страница 27: ...value 1 seconds 2 minutes Exit to I O Configurations Next Setting Cv3 Output Time is You Enter new value 1 to 65535 Exit to Main Menu Next Setting Menu items for Automatic On Off Outputs Relays 1 2 o...

Страница 28: ...e 0 NO contacts 1 NC contacts Exit to Main Menu Next setting Cv3 Output Scale is You Enter new value 1 seconds 2 minutes Exit to I O Configuration Next Setting Cv3 Output Time is You Enter new value 1...

Страница 29: ...etting Cv3 Interrogate Code is You Enter a new DTMF code Exit to Main Menu Next setting Cv3 Directory Timer is You Enter new value 1 to 255 min Exit to Main Menu Next setting Cv3 Acknowledge Request i...

Страница 30: ...sec steps Exit to Main Menu Next setting Cv3 Radio Volume One is minus TX Tone You Enter a new value 0 to 20 Exit to Main Menu Next setting Cv3 Radio Volume Two is minus TX DTMF You Enter a new value...

Страница 31: ...PROGRAMMING PAGE 27 Reset Database Cv3 Empty Program Cv3 Alert Enter Octo Three One Star Star You Confirm Exit to Main Menu Exit to Main Menu Cv3 Program is Empty...

Страница 32: ...rogate Phone Cv3 Signal Strength is 0 to 15 3 poor 6 good You Exit to Main Menu Next item Cv3 PRL is PRL You Exit to Main Menu Next item Cv3 SID is SID You Exit to Main Menu Next item Cv3 Roaming stat...

Страница 33: ...The Phone Control is a parameter predefined by the cellular service provider and is automatically programmed into the module Contact Barnett Technical Support prior to changing this parameter Cv3 Pro...

Страница 34: ...rsion Cv3 Serial Number is You Exit to Main Menu You Next Cv3 Hardware version is You Exit to Main Menu You Next Cv3 Firmware version is You Exit to Main Menu You Next Cv3 Options are You Exit to Main...

Страница 35: ...d Red see RSSI 0 RSSI 0 see No Service 4 Flashing Red Invalid MIN and no service Flashing Red 4 Flashing Red Invalid MIN and service Flashing Green 1 to 4 Solid Green Invalid MIN and roaming Flashing...

Страница 36: ...eaches the end of the directory without being acknowledged it will wait two minutes Directory Timer then start calling again beginning at the top of the directory In addition to making voice calls the...

Страница 37: ...phrase No Alarms and then prompt you to Enter Command Code The B1277 then waits ten seconds for you to enter one of the following user defined control codes Acknowledge code Interrogate code Totalize...

Страница 38: ...tem alarm If the input is disabled Off If the input is enabled Configured as an alarm input digital analog watchdog Idle no alarm Off Alarm is unacknowledged Flashing Red Alarm is acknowledged Solid R...

Страница 39: ...y Solid Red 4 SIGNAL Refer to the Signal Telephone Status table found on Page 32 5 OUTPUT 4 one for each output relay If the relay is in the idle state Off If the relay is in the ON state Solid Red If...

Страница 40: ...disconnected from the primary power source and operating from the internal battery pressing the power switch continuously for 5 seconds will cause the unit to power down Normal operation will be resto...

Страница 41: ...0 All inputs will withstand up to 30 VDC Inputs 1 to 6 Analog voltage mode Input impedance 210k ohm Range 0 to 5 or 0 to 30 VDC Digital mode Internal 4 7k ohm pull up resistor to 5 VDC Operates with g...

Страница 42: ...capacitor coupled Adjustable between 0 dBm and 20 dBm RX audio 600 ohms single ended capacitor coupled Adjustable between 0 dBm and 20 dBm Program Ports Telset RJ11 connector Internal telset bias fro...

Страница 43: ...TECHNICAL DRAWINGS PAGE 39 9 TECHNICAL DRAWINGS Unit Dimensions...

Страница 44: ...PAGE 40 TECHNICAL DRAWINGS Wiring Inputs Digital connection Inputs 1 through 6 Digital connection Inputs 7 through 10 Analog Connection DC Voltage Inputs 1 through 6...

Страница 45: ...TECHNICAL DRAWINGS PAGE 41 Analog Connection DC Voltage Inputs 7 through 10 Analog Connection DC Current Inputs 7 through 10...

Страница 46: ...low alarm setpoint with an accepted range on the input terminal of 0 to 5 VDC Carrier Operated Squelch an output from a radio that indicates the receiver squelch is open This signal is used by the Pro...

Страница 47: ...er a permanent 32 bit number embedded by the manufacturer that uniquely identifies a wireless communications device Group a means of having the alarms created by some inputs respond differently than t...

Страница 48: ...ush To Talk Pulse Width see Interval Input Push To Talk an output from the Cv3 that provides a ground closure when a radio transmission is required and an open circuit when idle a k a Push To Transmit...

Страница 49: ...support barnett engg com Product Repairs For all your repair needs please contact Barnett Engineering Ltd Barnett Engineering Ltd commits to a Repair Turnaround Time of thirty 30 business days on all...

Страница 50: ...ne on account of buyer 1 Consequential Damages Barnett Engineering Ltd shall not be liable for any incidental or consequential damages incurred as a result of any defect in any equipment sold hereunde...

Отзывы: