background image

6

Unpacking

Upon receiving the pump, it should be 
inspected for damage or shortages. 
If damage has occurred, fi le a claim 
immediately with the carrier that 
delivered the pump. If the manual is 
removed from the packaging, do not 
lose or misplace.

Storage

Short Term -

 Pumps are 

manufactured for effi cient 
performance following short 
inoperative periods in storage. For 
best results, pumps can be retained 
in storage, as factory assembled, 
in a dry atmosphere with constant 
temperatures for up to six (6) months.

Long Term -

 For storage of six (6) 

months, to twenty-four (24) months, 
the units should be stored in a 
temperature controlled area, a roofed 
over walled enclosure that 
provides protection from the elements 
(rain, snow, wind-blown dust, etc.), 
and whose temperature can be 
maintained b40° F and 
+120° F. If extended high humidity is 
expected to be a problem, all exposed 
parts should be inspected before 
storage and all surfaces that have the 
paint scratched, damaged, or worn 
should be recoated with a water base, 
air dry enamel paint. All surfaces 
should then be sprayed with a rust-in-
hibiting oil.

Pump should be stored in its 
original shipping container. On initial 
start up, rotate impeller by hand to 
assure seal and impeller rotate freely.

If it is required that the pump be 
in-stalled and tested before the long 
term storage begins, such installation 
will be allowed provided:

1. The pump is not installed under  

water for more than one (1) month.

2. Immediately upon satisfactory 

completion of the test, the pump is 
removed, thoroughly dried, 

 

repacked in the original shipping 
container, and placed in a 
temperature controlled storage 
area.

Installation

The basin should be located at the 
lowest point in the basement (or 
bottom fl oor) below fl oor level. The 
bottom of the basin should be level for 
proper pump operation.

Install 4” PVC schedule 40 Infl ow pipe 
(supplied by contractor) into fl exible 
pipe fi tting. The recommended level 
should not drop below the top of the 
motor housing. Finish connecting 
discharge piping and vent piping.

Level Controls

Figure 4 shows a typical installation 
for a level control mounted to the 
discharge piping with a piggy-back 
plug. 

Never work in the sump with 
the power ON.

1. Level controls are factory set for 

a pumping differential of 9”. If 
that is the cycle desired, simply 
circle the discharge pipe with the 
pipe  mounting strap, feed the end  
through and tighten. Be certain that 
the level control can not hang up or 
foul in it’s swing.

2. If a higher pump differential is 

needed, grip the cord near the 
neck  of the fl oat, then using the 
other  hand, exert a steady force on 
the  lower edge of the cable clamp.  
The cable clamp should slide up to  
the new pivot point. 

Automatic -

 Plug fl oat cord into 

outlet, then plug pump cord into fl oat 
cord.

Manual -

 Plug pump cord directly into 

outlet.

Содержание SE411

Страница 1: ...nt product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 126898 Rev E 41 Gallon Basin Packages Manual Index ...

Страница 2: ...her moving parts WARNING Keep clear of suction and discharge openings DO NOT insert fingers in pump with power connected Make sure lifting handles are securely fastened each time before lifting Do not operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Do not exceed manufacturers recommendation for maximum performance as this c...

Страница 3: ...mable Material Lubricating Oil and or Grease Strong Chemicals Gasoline Power Failure Your pump cannot dispose of wastewater or provide an alarm signal without electrical power If electrical power service is interrupted keep water usage to a minimum Warranty Your pump is furnished with a warranty against defects in material or workmanship A properly completed Start Up Warranty Registration form mus...

Страница 4: ... lavatories laundry tubs floor drains and water closets Pumps push the water from below ground up to where normal drainage will handle it The package system shall NOT be installed in locations classified as hazardous in accordance with the United States National Electrical Code NEC ANSI NFPA 70 and shall be vented in accordance with local plumbing codes NOTE Pre Assembled units contain water solua...

Страница 5: ...5 inches mm Basins ...

Страница 6: ...e the long term storage begins such installation will be allowed provided 1 The pump is not installed under water for more than one 1 month 2 Immediately upon satisfactory completion of the test the pump is removed thoroughly dried repacked in the original shipping container and placed in a temperature controlled storage area Installation The basin should be located at the lowest point in the base...

Страница 7: ...ottom of the basin to hold it in place Do not use sand or native soil as backfill Make the inlet connection as required for your basin C Inlet Connection The basins have a 4 inlet molded to the side of the tank This inlet is sized to accept a 4 no hub type coupling Connect the gravity drainage line from the fixtures to this hub D Final Backfill Large rocks clods and foreign objects should be kept ...

Страница 8: ...essary A check valve is required to prevent the backflow of liquid after each pumping cycle A gate or ball valve should follow the check valve to allow periodic cleaning of the check valve or removal of the pump The remainder of the discharge line should be as short as possible with a minimum number of turns to minimize friction head loss Do not restrict the discharge below 2 in sewage application...

Страница 9: ... Basin pack ages feature a manual pump with no switch attached directly to the pump Operation of the pump is accomplished by the Floatree system Re inserting the Floatree After service or inspection of the floats re insert the Floatree into its holder Cords from the pump float switch and optional alarm need to be properly sealed as described below in the cord seal Cord Seal It is important that co...

Страница 10: ...10 ...

Страница 11: ...pump by the power cord 5 Do not exceed manufacturer s recommendation for maximum performance as this could cause the motor to overheat 6 Secure the pump in its operating position so it can not tip over fall or slide 7 Keep hands and feet away from impeller when power is connected Submersible pumps are notapproved for use in swimming pools recreational water installa tions decorative fountains or a...

Страница 12: ...time the motor rotation must be checked Improper motor rotation can result in poor pump performance and can damage the motor and or pump To check the rotation suspend the pump freely momentarily apply power and observe the kickback Kickback should always be in a counter clockwise direction as viewed from the top of the pump kickback is always opposite to impeller rotation Rotation and kickback dir...

Страница 13: ...ctions 6 Make sure liquid level is at least equal to sug gested turn on point Pump will not turn off 1 Float movement restricted 2 Switch will not activate pump or is defective 3 Excessive inflow or pump not properly sized for ap plication 4 Pump may be airlocked 1 Reposition pump or clean basin as required to provide adequate clearance for float 2 Disconnect level control Set ohmmeter for a low r...

Страница 14: ...otector Pump may start unexpectedly Disconnect power supply NOTE Some pumps do not have thermal load protec tion on the motor Check pump specifications to determine 1 Incorrect voltage 2 Excessive inflow or pump not properly sized for ap plication 3 Impeller jammed loose on shaft worn or damaged impeller cavity or inlet plugged 4 Excessive water tempera ture internal protection only 1 Check all el...

Страница 15: ...15 Ref No Description Part No Qty 1 Basin Split Cover See BOM 1 3 Post Float 126893 1 4 Check Valve 126895 1 5 Discharge 2 104601 1 6 Float Mech See BOM 1 7 Manual 126898 1 8 Pump See BOM 1 ...

Страница 16: ... between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE EXPERIENCE AND PUBLISHED INDUSTRY INFORMATION SUCH RECOMMENDATIONS DO NOT CONSTITUTE A WARRANTY OF SATISFACTORY PERFOR...

Страница 17: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Страница 18: ...Notes ...

Отзывы: