14
Motor Housing
NOTE:
Position unit upright, using 4” PVC
coupler to avoid resting unit on the lower
shaft.
Loosen 5/16” hex bolts and lockwashers from cable clamp on motor housing. Remove cord from motor
housing by pulling straight up while using a rocking motion.
Remove retaining snap ring with a medium fl at tip screwdriver. Using a 1/4-20 bolt, thread it into
the center of the terminal block. Pull straight up with a rocking motion to remove the terminal block.
Disconnect all wire connections noting where each wire is connected. The bottom of the block has a
number located next to each pin for reference. If pump is equipped with automatic level control, remove
in same manner as the power cord.