SECTION B: GENERAL INFORMATION

B-1) To the Purchaser:

Congratulations! You are the owner of one of the fi nest 
pumps on the market today. CP&S pumps are products 
engineered and manufactured of high quality compo-
nents. Over one hundred years of pump building experi-
ence along with a continuing quality assurance program 
combine to produce a pump which will stand up to the 
toughest applications.

This manual will provide helpful information concerning 
installation, maintenance, and proper service guidelines.

B-2) Receiving:

Upon receiving the pump, it should be inspected for dam-
age or shortages. If damage has occurred, fi le a claim 
immediately with the company that delivered the pump. If 
the manual is removed from the packaging, do not lose or 
misplace.

B-3) Storage:
Short Term-

 CP&S Pumps are manufactured for effi cient 

performance following short inoperative periods in stor-
age. For best results, pumps can be retained in storage, 
as factory assembled, in a dry atmosphere with constant 
temperatures for up to six (6) months.

Long Term-

 Any length of time exceeding six (6) months, 

but not more than twenty-four (24) months. The unit 
should be stored in a temperature controlled area, a 
roofed over walled enclosure that provides protection 
from the elements (rain, snow, wind-blown dust, etc.), and 
whose temperature can be maintained b40 deg. 
F and +120 deg. F. (4.4 - 49°C).

Pump should be stored in its original shipping container. 
On initial start up, rotate impeller by hand to assure seal 
and impeller rotate freely. If it is required that the pump be 
installed and tested before the long term storage begins, 
such installation will be allowed provided:

1.)  The pump is not installed under water for more than
 

one (1) month.

2.)  Immediately upon satisfactory completion of the test,
 

the pump is removed, thoroughly dried, repacked in

 

the original shipping container, and placed in a 

 

temperature controlled storage area.

B-4) Service Centers:

For the location of the nearest Barnes or Prosser Center, 
check your Barnes or Prosser representative or 
Crane Pumps & Systems, Inc., Service Department in 
Piqua, Ohio, telephone (937) 778-8947 or Crane Pumps & 
Systems Canada, in Brampton, Ontario, (905) 457-6223.

SECTION C: INSTALLATION

C-1) Location:

These pumps are recommended for general and light 
construction, for sump and dewatering drainage, for dewa-
tering manholes and transformer vaults, for pit, tunnel and 
trench dewatering, and for fl ood, fi re and other emergency 
service cleanup.

Before pumping fl uids other than water, consult the 
factory, giving fl uid, fl uid temperature, specifi c gravity, 
viscosity, capacity in USGPM and total head and/or pres-
sure requirements, including friction loss through dis-
charge line, fi ttings, valves, etc. Pump may run dry for 5 to 
10 minutes in air without damage where air can circulate 
freely through the pump. 

DO NOT

 allow pump to be bur-

ied in mud or sand.

C-2) Discharge:

Discharge hose is recommended. If rigid pipe is used, 
install so that there is no weight or strain on the pump.

C-3) Liquid Level Controls: (If Applicable)

Attach “ON” fl oat to discharge hose or pump cable at 
desired pump “ON” level. Attach “OFF” fl oat to discharge 
hose or pump cable at desired pump “OFF” level. The 
“OFF” fl oat must be below the “ON” fl oat. To attach the 
fl oats, thread the cable strap through the buckle with 
the ratchet pawl, cinch up tight, thread excess strapping 
through outer buckle slot. Be certain the level controls 
cannot hang up or foul in its swing. It is recommended that 
the pump is completely submerged when the level control 
is in the “OFF” mode.

C-4.1) Electrical Connections:

The pump comes with a three wire cord and a three prong 
grounded plug on the 120 volt models and a three wire cord 
without a plug on the 240 volt models.

The 120 volt model’s cord assembly should not be 
modifi ed in any way and must be connected into a three 
wire grounded Ground Fault receptacle.

There are many different prong confi gurations for 240 volt 
applications. An appropriate 240 volt plug to match your 
receptacle will be required. Make sure the plug meets the 
pump amp requirements found on the nameplate. Follow 
the plug manufacturer’s wiring installation instructions.

DO NOT USE THE POWER CABLE TO LIFT PUMP.

C-4.2) Overload Protection:

An automatic thermal overload protects the motor. The 
type of in-winding overload protector used is referred to 
as an inherent overheating protector and operates on the 
combined effect of temperature and current. This means 
that the overload protector will trip out and shut the pump 
off if the windings become too hot or the current passing 
through them becomes too high. 

Содержание 70 Series

Страница 1: ...ram product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada...

Страница 2: ...sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair S...

Страница 3: ...Polypropylene 25 Ft 7 6m STRAINER 25 6mm Openings Non Metallic LIFTING HANDLE Non Matallic PUMP SPECIFICATIONS MODEL NO BARNES PART NO PROSSER PART NO A Dim Inch mm HP VOLT PH HERTZ RPM FULL LOAD AMPS...

Страница 4: ...C INSTALLATION C 1 Location These pumps are recommended for general and light construction for sump and dewatering drainage for dewa tering manholes and transformer vaults for pit tunnel and trench de...

Страница 5: ...t duplicates thereof shall be used E 4 Fasteners All bolts nuts screws and other means of fastenings shall be in place properly tightened and secured E 5 Cable Requirements Special care shall be taken...

Страница 6: ...ded with the Repair Parts Kit F 4 Power Supply Cord Replacement Please refer to instructions included with the Repair Parts Kit F 5 Discharge Nozzle Replacement Please refer to instructions included w...

Страница 7: ...r freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the s...

Страница 8: ...8 Figure 2...

Страница 9: ...Seal Plate 19 4 115135 RdHd Screw M5 x 10 SS 20 3 115139 Impeller Shim 21 1 115121 115122 0 7 HP 70 71 Series Impeller 1 25 HP 125 126 Series Impeller 22 1 115143 Lockwasher 8mm SS 23 1 115103 O ring...

Страница 10: ...between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM...

Страница 11: ...t To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by th...

Страница 12: ...Notes...

Отзывы: