background image

3

DISCHARGE .......................

2” NPT (M), Vertical

LIQUID TEMPERATURE ....

104°F (40°C) Max.

VOLUTE ..............................

Non-Metallic

MOTOR SHELL ..................

Stainless Steel

IMPELLER ..........................

Non-Matallic

SHAFT .................................

420

 

Stainless Steel

HARDWARE .......................

300 Series Stainless Steel

SEAL

 

Design

 .............

Tandem Mechanical, Oil-Filled 

 

 

Reservoir

 

Material:

 

Stationary Face.

Silicon/Carbide, Pump End

 

 

Ceramic, Motor End

 

Rotating Face

 ... Carbon

 

Elastomer

 ......... Buna-N

 

Hardware

 .......... 300 series stainless steel

CORD ENTRY .....................

50 Ft. (15m) Cord with Plug on 120 

  

Volt. Molded for strain relief and

 

compression seal

SPEED ................................

3450 RPM (Nominal)

MOTOR:

 

Design

 .............

NEMA Design L-Single Phase, 

 

 

Air-Filled, Squirrel Cage Induction

 

Insulation

 ........

Class F

SINGLE PHASE ..................

Capacitor Start and Run

 

Includes Overload protection in motor

LIFTING ROPE ...................

3/8” (9.7mm) Polypropylene,

 

25 Ft (7.6m)

STRAINER ..........................

.25” (6mm) Openings, Non-Metallic

LIFTING HANDLE ...............

Non-Matallic

PUMP SPECIFICATIONS:

MODEL NO.

BARNES

PART NO.

PROSSER

PART NO.

A - Dim

Inch (mm)

HP

VOLT

PH

HERTZ

RPM

FULL LOAD 

AMPS

70

115070

115165

17.76 (451)

0.7

120

1

60

3450

8.0

71

115071

115166

17.76 (451)

0.7

240

1

60

3450

4.0

125

115125

115167

18.54 (471)

1.25

120

1

60

3450

15.0

126

115126

115168

18.54 (471)

1.25

240

1

60

3450

7.6

inches

(mm)

Plug On 120 Volt Only

IMPORTANT !

1.) 

PUMP MAY BE OPERATED 

“DRY”

 FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS. 

2.) 

INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN

 

ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT

 

INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH

 

PUMPED MEDIA IS A COMMON OCCURRENCE.

Содержание 70 Series

Страница 1: ...ram product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada...

Страница 2: ...sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair S...

Страница 3: ...Polypropylene 25 Ft 7 6m STRAINER 25 6mm Openings Non Metallic LIFTING HANDLE Non Matallic PUMP SPECIFICATIONS MODEL NO BARNES PART NO PROSSER PART NO A Dim Inch mm HP VOLT PH HERTZ RPM FULL LOAD AMPS...

Страница 4: ...C INSTALLATION C 1 Location These pumps are recommended for general and light construction for sump and dewatering drainage for dewa tering manholes and transformer vaults for pit tunnel and trench de...

Страница 5: ...t duplicates thereof shall be used E 4 Fasteners All bolts nuts screws and other means of fastenings shall be in place properly tightened and secured E 5 Cable Requirements Special care shall be taken...

Страница 6: ...ded with the Repair Parts Kit F 4 Power Supply Cord Replacement Please refer to instructions included with the Repair Parts Kit F 5 Discharge Nozzle Replacement Please refer to instructions included w...

Страница 7: ...r freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the s...

Страница 8: ...8 Figure 2...

Страница 9: ...Seal Plate 19 4 115135 RdHd Screw M5 x 10 SS 20 3 115139 Impeller Shim 21 1 115121 115122 0 7 HP 70 71 Series Impeller 1 25 HP 125 126 Series Impeller 22 1 115143 Lockwasher 8mm SS 23 1 115103 O ring...

Страница 10: ...between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM...

Страница 11: ...t To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by th...

Страница 12: ...Notes...

Отзывы: