inches
(mm)
SECTION: A- PUMP SPECIFICATIONS - 4SE-EL
DISCHARGE:
4" (102mm) 125 lb, Horizontal
LIQUID TEMPERATURE:
104°F (40°C) Continuous.
VOLUTE:
Cast Iron ASTM A-48, Class 30.
MOTOR HOUSING:
Cast Iron ASTM A-48, Class 30.
SEAL PLATE:
Cast Iron ASTM A-48, Class 30.
IMPELLER:
Design:
2 Port, Enclosed. Dynamically
Balanced, ISO G6.3, with Bronze
Wear Ring.
Material:
Cast Iron ASTM A-48 Class 30.
SHAFT:
416 Stainless Steel
SQUARE RINGS:
Buna-N
DIAPHRAGM:
Polyester and Nitrile.
HARDWARE:
300 Series Stainless Steel
LIFTING CHAIN:
Yoke, Galvanized
PAINT:
Air Dry Enamel.
SEAL:
Design:
Single Mechanical, Oil-Filled Reservoir.
Material:
Rotating Face - Carbon
Stationary Face - Ceramic
Elastomer - Buna-N
Hardware - 300 Series Stainless
CABLE ENTRY:
15 ft. (4.6M) Cord on 1.5HP
25 ft. (7.6M) Cord on 2.2 thru 6.7HP,
Pressure Grommet For Sealing And
Strain Relief
.
Sealed Junction
Chamber With Terminal Block.
SPEED:
1750 RPM (Nominal)
UPPER BEARING:
Design:
Single Row, Ball
Lubrication:
Oil
Load:
Radial
LOWER BEARING:
Design:
Single Row, Ball
Lubrication:
Oil
Load:
Radial & Thrust
MOTOR:
Design:
NEMA L-Single Phase, NEMA B-Three
Phase Torque Curve. Completely
Oil-Filled, Squirrel Cage Induction
Insulation:
Class
A
SINGLE PHASE:
Dual Voltage, 200-230;
Includes Overload Protection In Motor.
1.5 & 2.2HP Capacitor Start.
2.7 & 4.5HP Capacitor Start/Capacitor
Run. Requires Barnes
®
Pumps’ Starter
or Control Panel Which Includes,
Capacitors, or Capacitor Pack.
THREE PHASE:
Dual Voltage 200-230;
Includes Overload Protection in Motor.
OPTIONAL EQUIPMENT:
Seal Material, Impeller Trims,
Additional Cable.
"A"
19.12
(486)
20.63
(524)
See Chart
on Page 6.
5.56
(141)
14.75
(375)
8.50
(216)
6.06
(154)
10.93
(278)
IMPORTANT !
1.) PUMP MAY BE OPERATED
"DRY"
FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS.
2.) THIS PUMP
IS
APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION II HAZARDOUS LOCATIONS.
3.) THIS PUMP IS
NOT
APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION I HAZARDOUS LOCATIONS.
4.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT
INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED
MEDIA IS A COMMON OCCURRENCE.
4
Содержание 4SE-EDS Series
Страница 15: ...Fig 15 SINGLE PHASE 1 5HP 2 2HP Fig 16 SINGLE PHASE 2 7HP 4 5HP Fig 17 THREE PHASE 15...
Страница 18: ...Fig 19 SERIES 4SE EL 18...
Страница 19: ...Fig 20 SERIES 4SE EL 19...
Страница 22: ...SERIES 4SE EDS Fig 21 22...
Страница 23: ...SERIES 4SE EDS Fig 22 23...
Страница 27: ...SERIES 4SE EDS Fig 23 27...