Barnes 4CDD6 Скачать руководство пользователя страница 3

3

Please Read This Before Installing Or Operating Pump. 
This information is provided for 

SAFETY and to PREVENT 

EQUIPMENT PROBLEMS

. To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury or Indicates factors concerned with 
assembly, installation, operation, or maintenance which 
could result in damage to the machine or equipment if 
ignored.

CAUTION !

 Warns about hazards that can or will cause minor 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING !

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only qualifi ed personnel should install, operate and repair pump.   

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 
and seal failure on any pump, and on end 
suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 
pressures. It is recommended that a high case temperature 
switch or pressure relief valve be installed on the pump body.

CAUTION! 

Pumps build up heat and pressure 

during operation-allow time for pumps to cool 
before handling or servicing. 

WARNING!

 - 

DO NOT

 pump hazardous materials 

(fl ammable, caustic, etc.) unless the pump is specifi cally 
designed and designated to handle them.

CAUTION! 

- Do not block or restrict discharge hose, as 

discharge hose may whip under pressure. 

WARNING! - DO NOT

 wear loose clothing that may 

become entangled in the impeller or other moving parts. 
Always wear appropriate safety gear, such as safety 
glasses, when working on the pump or piping. 

WARNING! - 

Keep clear of suction and discharge 

openings. 

DO NOT

 insert fi ngers in pump with power 

connected.

Always wear eye protection when working on pumps.

Make sure lifting handles are securely fastened each 
time before lifting. 

DO NOT

 operate pump without 

safety devices in place. Always replace safety devices 
that have been removed during service or repair. 
Secure the pump in its operating position so it can not 
tip over, fall or slide.

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor 
to overheat.

When towing pump behind a vehicle, make sure hitch is 
properly attached, always attach safety chains.

WARNING!

 If Engine driven, never operate in an 

enclosed building or area where exhaust gases can 
accumulate. Never operate near a building where 
exhaust gases can seep inside. Never operate in a 
pit or sump without making provisions for adequate 
ventilation.

WARNING!

 Do not breathe exhaust fumes when 

working in the area of the engine. (Exhaust gases are 
odorless and deadly poison.)

WARNING!

 Allow exhaust system to cool before 

touching.

Never add fuel to the tank while the engine is running.
Stop engine and allow to cool.
Do not smoke while refueling the engine
Do not refuel near open fl ame

Carefully read instruction manuals supplied by engine 
manufacture before attempting to assemble, operate 
or service the engine or any part. The “WARNING” 
statements indicate potentially hazardous conditions for 
operator or equipment.

WARNING! 

Products Returned Must Be Cleaned, 

Sanitized, Or Decontaminated As Necessary Prior 
To Shipment, To Insure That Employees Will Not Be 
Exposed To Health Hazards In Handling Said Material. 
All Applicable Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass fi tted pumps may 
contain lead levels higher than considered safe for 
potable water systems. Lead is known to cause cancer 
and birth defects or other reproductive harm. Various 
government agencies have determined that leaded 
copper alloys should not be used in potable water 
applications. For non-leaded copper alloy materials of 
construction, please contact factory. 

IMPORTANT! -

 Crane Pumps & Systems, Inc. is not 

responsible for losses, injury, or death resulting from a 
failure to observe these safety precautions, misuse or 
abuse of pumps or equipment.

SAFETY FIRST!

Hazardous fl uids can 
cause fi re or explo-
sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous fl uids can Hazard-
ous pressure, eruptions or ex-
plosions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Toxic Fumes - 
Breathing can cause 
nausea, fainting or death

Eye protectiong required

Содержание 4CDD6

Страница 1: ...uct improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 4...

Страница 2: ...TION 12 RETURNED GOODS POLICY 13 WARRANTY 14 START UP REPORT 17 18 WARRANTY REGISTRATION Other brand and product names are trademarks or registered trademarks of their respective holders Barnes is a r...

Страница 3: ...commendation for maximum performance as this could cause the motor to overheat When towing pump behind a vehicle make sure hitch is properly attached always attach safety chains WARNING If Engine driv...

Страница 4: ...er minute SKID Steel 4CDD6 ENGINE Make Model Hatz 1B20 w 6 1 Reduction Recoil Diesel Rating 4 6HP 3600RPM Tank Run TIme 79 Gal US 3Hr 4CDG8 ENGINE Make Model Honda GX240 w 6 1 Reduction Recoil Gasolin...

Страница 5: ...AP VALVE Natural Rubber PAINT Air Dry Enamel OUTPUT STROKES 60 Per Minute Note Speed may be adjusted between approx 50 and 65 strokes per minute TIRES 4CDD6 2 4CDG8 2 4 x 8 Industrial Tires TRAILER 4C...

Страница 6: ...in good condition When using pipe coat the threads with a thread sealing compound Suction hose must be in good condition with no leaks and lining tight A loose lining will collapse under suction and k...

Страница 7: ...nner lining has loosened If loose pump suction will cause lining to collapse and block hose 3 Valves may not be seating properly due to accumulation of residue or wear Pour water in suction and discha...

Страница 8: ...8 Figure 2 Figure 1...

Страница 9: ...9 Figure 3...

Страница 10: ...ut 28 1 P1854 Connecting Rod End 29 1 P3698 1 11 16 Needle Bearing 30 1 P1856A Crank Pin Hub with Dowel Pin 31 1 P1857 Crank Pin Washer 32 1 Hex Screw 5 8 x 1 1 2 LW 33 2 1 4 1 Grease Cup 34 1 P2191 B...

Страница 11: ...acket 95 1 PM440L Tail Light Left 96 1 PM440 Tail Light Right 97 2 9103305 Grease Seal 98 2 9089137 Hub Idler 5 Bolt on 4 1 2 BC 99 2 L44610 Outer Bearing Cup 100 2 L44649 Outer Bearing Cone 101 2 919...

Страница 12: ...12 Figure 4...

Страница 13: ...o Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the e...

Страница 14: ...guarantees in the nature of performance speci cations furnished in addition to the foregoing material and workmanship warranties on a product manufactured by us if any are subject to laboratory tests...

Страница 15: ...15 Notes...

Страница 16: ...16 Notes...

Страница 17: ...ation of Installation Person in Charge Phone Purchased From Crane Pumps Systems Representative Distributor Pump Model Serial No Part Number Trailer type Skid Mounted Contractor Trailer Highway Trailer...

Страница 18: ...of Company Date I Certify this report to be accurate Name of Start Up Person Employed By Date Date and Time of Start Up Present at Start Up Engineer Operator Contractor Other TO BE FILLED OUT BY FACT...

Страница 19: ...CITY STATE ZIP MODEL NO SERIAL NO PART NO BRAND IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and return to Crane Pumps Syst...

Страница 20: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA OHIO 45356 U S A FOLD HERE AND TAPE DO NOT STAPLE PLACE STAMP HERE...

Отзывы: