background image

10

Installation & Connection

Handling

When lifting the pump, use the motor eyebolts.

Installation

The pump should be installed in a well ventilated and frost-free position. The distance between pump-

motor and other objects should be at least 6 inches in order to have enough air to cool the motor.

The inlet pipe shall be as short as possible in order to reduce the head loss of the inlet.

Ensure that the check valve is installed in the pipe line system before the pump is installed. If pump is 

used for boiler water supply, a check valve must be installed in the piping between pump and boiler.

Pump  shall  be  installed  in  a  concrete  base  or  other  similar  base  with  suitable  height.  It  can  also  be 

installed in fixed grounds or fixed brackets on the wall.

Pay attention not to let the weight of pipe system on pump to prevent pump from damage.

When installation, motor is not allowed to be hung upside down.

Arrow on the inlet and outlet chamber shows the direction of flow of liquid through the pump. Check 

whether the liquid can flow easily before starting pump.

Before  pump  installation,  the  inlet  pipe  line  shall  be  cleaned.  If  there  is  impurities  in  the  pipe,  it  is 

necessary to install a strainer at 20 - 40 inches in front of the pump inlet (particularly recommended for 
pump with flow less than 8 m³/h).

The air locks shall be avoided when installing the inlet pipe line. See Fig. 3.

If the outlet globe valve might be closed (or the flow is decreased to be zero), a bypass shall be installed 

in outlet pipeline to ensure adequate lubricating and cooling water to pass the pump.

CAUTION

Figure 2

Figure 3

Air

Air

Air

Wrong

Correct

barmesapumps.com

Содержание BMV Series

Страница 1: ...BMV series Installation Operation Maintenance Manual Vertical Multi Stage IMPORTANT Read all instructions in this manual before operating or servicing a pump barmesapumps com...

Страница 2: ...not insert fingers in pump with power connected the rotating cutter and or impeller can cause serious injury Always wear eye protection when working on pumps Do not wear loose clothing that may becom...

Страница 3: ...pplications Pumped liquids low viscosity neutral non explosive liquids not containing solid particles or fibres The liquid must not attack the pump materials chemically Boiler water supply and condens...

Страница 4: ...nclature Nameplate To each pumping equipment is placed an identification plate as shown below 03 Definition of Model B M V 1 2 5 0 3 0 3 PHASE HP STAGE x10 RATED FLOW m h MULTI STAGE PUMP barmesapumps...

Страница 5: ...Refer to Fig 1 Key parts of the pump diffuser impeller cylinder shaft arc all made of stainless steel Also the material of pump head and inlet outlet chamber is made of stainless steel Mechanical seal...

Страница 6: ...T M8 WASHER 8 1 KIT 33 INDUCER 1 Pc 34 CYLINDER 1 Pc 35 FLANGE TYPE INLET OUTLET CHAMBER 1 Pc 36 CIRCLIP 2 Pc 37 FLANGE 2 Pc 38 FLANGE TYPE BASE PLATE 1 Pc 39 O RING RETAINER 1 Pc 40 O RING 8mm x 2 65...

Страница 7: ...10 15 27 23 24 25 29 30 23 32 33 41 42 14 43 44 28 31 24 25 35 34 36 37 23 24 25 22 26 38 39 40 Figure 1B BMV8 BMV20 For Repair Part Please supply Model Number and Serial as shown on Name Plate and P...

Страница 8: ...ELLER SLEEVE S 1 Pc 32 FIRST IMPELLER COVER 1 Pc 33 NUT M12 WASHER 12 1 KIT 34 STRAP 2 Pc 35 INDUCER 1 Pc 36 SCREW M8x20 2 Pc 37 FLANGE TYPE INLET OUTLET CHAMBER 1 Pc 38 CIRCLIP 2 Pc 39 FLANGE 2 Pc 40...

Страница 9: ...8 18 22 23 19 28 29 30 31 26 27 32 33 27 28 29 30 34 26 27 28 29 30 35 36 38 37 44 39 43 42 15 13 41 40 Figure 1C BMV32 BMV65 For Repair Part Please supply Model Number and Serial as shown on Name Pla...

Страница 10: ...RT DIFFUSER 1 Pc 32 INTERMEDIATE BEARING 1 Pc 33 IMPELLER NUT FOR SUPPORT DIFFUSER 1 Pc 34 DIFFUSER 1 Pc 35 INDUCER 1 Pc 36 BOTTOM BEARING 1 Pc 37 SOCKET HEAD SCREW WASHER 4 KIT 38 BOTTOM SLEEVE 1 Pc...

Страница 11: ...ds or fixed brackets on the wall Pay attention not to let the weight of pipe system on pump to prevent pump from damage When installation motor is not allowed to be hung upside down Arrow on the inlet...

Страница 12: ...2 BMV1 BMV2 BMV3 BMV4 BMV8 BMV12 BMV16 BMV20 BMV32 BMV42 BMV65 DN 32 40 65 80 100 P1 107 120 150 P1 100 110 145 160 180 P2 140 145 185 200 220 n D1 C 280 320 365 380 E 80 105 H 25 30 RATED FLOW PN25 4...

Страница 13: ...4 10 8 192 BMV8 140 1503 33 19 52 13 10 291 BMV12 20 303 14 11 26 7 6 84 BMV12 50 753 19 17 36 10 8 159 BMV12 70 1003 22 17 38 10 8 159 BMV12 100 1503 29 19 48 13 10 324 BMV12 140 2003 33 19 53 13 10...

Страница 14: ...or EN 60204 1 as well as by the national rules of the country where the pump is used Despite the rules of any country the power supply to the pump unit must be equipped with at least following electr...

Страница 15: ...let pipeline In open system fill water in pump when liquid surface is lower than pump A check valve shall be installed in the inlet pipe Close the pump outlet valve release air vent screw and fill the...

Страница 16: ...s installed according to this installation manual will work effectively and require a little maintenance Mechanical seal will be adjusted automatically the moving part and stationary part is lubricate...

Страница 17: ...the space between the two couplings should be equal Tighten fixing bolts in mechanical seal rotate the coupling to ensure that the shaft can rotate freely and not be choked Reverse the process above...

Страница 18: ...the inlet outlet chamber fit on O ring lubricate the O ring and then put on the cylinder Fit stay bolts on the base plate then fit the O ring adjusting rubber air vent gag on the pump head and put th...

Страница 19: ...d setting b Periodic power supply faults b Check power supply c Low voltage at peak times c Add regulator a Contacts of starter are not contacted welI or the coil is faulty a Change motor starter b Co...

Страница 20: ...ed position c Check and repair foot valve d There is air in suction pipe d Check and repair suction a Leakage in suction pipe a Check and repair suction pipe b Suction pipe is too small or suction pip...

Страница 21: ......

Страница 22: ......