6  Network Settings

In the IP Former Settings page there are parameters used to configure your device with the desired network settings. To set the 
network settings:

Wire your IP Former to a network where a DHCP server is available and switch it on, hear the IP announced over the audio 

output (SonicIP

® function) and connect to its web browser

Locate the Network Settings in the "Settings" menu
Once settings are configured as desired click on Submit at the bottom of the page, the device will restart and if the IP is 

changed you must input the new address in the top bar 

7  Update the Firmware of IP Former

It is always good practice to run the latest firmware on the IP Former. Latest Firmwares includes improvements and bug fixes. The 
firmware on the IP Former can be updated using the local web interface.

To update the firmware from the web user interface you need first to download the TAR package from the Barix 

website: 

www.barix.com/downloads

 (Firmware is under Products 

 Decoder 

 IP Former) or simply type: IP Former in the search 

bar in the same page. In this page are available only the latest firmware from Barix.

Once the package is downloaded:

Содержание TPA400

Страница 1: ...ction to the Speaker Equipment through the screw connector provided on the front panel of the device The speaker output supports speaker impedance of 4 and 8 ohms 2 ohms is also possible but the output power of the amplifier is optimized and configurable to match 4 and 8 ohms speakers 2 2 STEP 2 Connecting to a PoE switch Connect your IP Former to the Network using a standard Ethernet cable CAT5e ...

Страница 2: ...igures the IP Former to receive an HTTP or HTTPS stream SIP configures the IP Former to be a SIP client peer to peer or Server mode Local File allows to play audio files which are locally stored on the IP Former Please refer to the help description in the user interface in order to properly configure your sources Individual Volume can be set for every of the sources 1 2 3 4 Tips for a proper start...

Страница 3: ...stream will be played over another configured stream 3 4 STEP 4 Manage Local Files Use the menu item Audio Files in order to manage your local files for the source type Local Files Example Example of a Priority System Priority 3 HTTP Radio Stream playing Background music Priority 2 RTP Streams playing ads over the background music Background music will stop as soon as the RTP stream is present Pri...

Страница 4: ...r can be controlled on the Settings page of the web interface The device supports MP3 AAC FLAC AC3 DTS OGG WAV files The filenames should NOT contain special characters and must have maximum one space character in the name The limit of individual files to be uploaded is 16MB It is possible to upload zip archives to upload multiple files at once Read the help side bar to know how to trigger the pla...

Страница 5: ...mer Every source status also includes a counter indicating how many times the actual source has been played 4 Remote Configuration Tool Any IP Former device present in the network has a tab called Remote Config exposed in the web UI The configuration tool lists all the devices automatically discovered in the network and allow bulk or individual configuration of them to make a system wise configura...

Страница 6: ...pen the webUI of another device perform a sound test of a device Immediately view how many devices are in the network See which source the device is playing green cells For more details on how to use the tool read the help side bar accessible clicking on the in the right upper side of the page 5 Security Settings These settings are among the most important in the Settings page of the IP Former In ...

Страница 7: ...ired click on Submit at the bottom of the page the device will restart and if the IP is changed you must input the new address in the top bar 7 Update the Firmware of IP Former It is always good practice to run the latest firmware on the IP Former Latest Firmwares includes improvements and bug fixes The firmware on the IP Former can be updated using the local web interface To update the firmware f...

Страница 8: ...n the device Soft Reset from web user interface Connect to the web user interface of the IP Former and navigate to the DEFAULTS tab Click on Reset Factory Defaults to perform a reset of the device Hard Reset A hard reset restore all values and settings on the IP Former To perform a hard reset Switch on the IP Former Press the reset button located in the front panel of the device and keep it presse...

Страница 9: ...utton pressed for approximately 10 seconds will reset the device and restore the factory default settings when the button is released LAN Ethernet RJ45 Pin Description 1 TX Transmit data V mode A 2 TX Transmit data V mode A 3 RX Receive data V mode A 4 5 V mode B 6 RX Receive data V mode A 7 8 V mode B Left LED Yellow Activity Left LED Green Link Speed Blinking SYSTEM STATUS LED Dual Color green r...

Страница 10: ...and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the device into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Safety and precaution re...

Отзывы: