36
account of the sides of the rows. Each plant has two sides, and then you have to
consider whether treating them together in one time or more.
Looking in the drawing here under it would be more
understandable:
“a " the distance is equal to half of "D" having to
spray only half row.
.
"b" the distance is equal to "D" having to spray half row on the right and half row on
the left.
.
"c" it's possible to spray 2 complete rows in one time, and then the distance would be 2D (
doubled).
once getting the distance (in meters) proceed as in § 4.4.1 using the table about
nozzle flow (. tab. 5)
TABLE 5.ATOMIZER NOZZLES "PNEUS" AT LOW VOLUME
Hole
nozzle
Mounting
verse
Bar
1 BAR
1,5 BAR
2 BAR
2,5 BAR
3 BAR
3,5 BAR
4 BAR
4,5 BAR
5 BAR
L/min
L/min
L/min
L/min
L/min
L/min
L/min
L/min
L/min
0,8
0,42
0,47
0,57
0,62
0,67
0,72
0,75
0,77
0,82
0,32
0,37
0,44
0,49
0,54
0,58
0,61
0,63
0,66
1
0,72
0,80
0,95
1,15
1,20
1,25
1,30
1,36
1,42
0,45
0,51
0,62
0,68
0,75
0,81
0,86
0,92
0,96
1,2
1,00
1,15
1,35
1,45
1,60
1,70
1,80
1,84
1,91
0,62
0,70
0,86
0,96
1,04
1,13
1,20
1,27
1,34
1,5
1,45
1,65
1,85
2,15
2,35
2,50
2,65
2,75
2,85
1,10
1,20
1,45
1,65
1,80
1,90
2,00
2,10
2,21
1,8
1,95
2,20
2,70
2,90
3,20
3,40
3,60
3,75
3,90
1,50
1,70
2,10
2,35
2,50
2,70
2,90
3,00
3,15
2
2,55
2,85
3,50
3,85
4,20
4,50
4,80
5,05
5,32
1,80
2,00
2,45
2,75
2,95
3,20
3,40
3,60
3,70
2,3
3,20
3,50
4,25
4,70
5,20
5,50
5,80
6,10
6,40
2,35
2,65
3,25
3,60
3,90
4,20
4,50
4,75
5,00