56-101-01175 Revision P Page | 46
4.
Leak Testing:
There are two methods available to perform Leak Testing using the Test
Set (refer to Figure 50).
Figure 50
Leak Testing Menu(s)
a)
Method (1)
Leak Rate Timer:
This traditional method uses the Leak Rate Timer
where the user first establishes a given CAS and ALT and uses the Leak Rate Timer
to measure the Leak Rate.
b)
Method (2)
ATP Leak Test:
The Test Set has an automated feature called ATP
Leak Test which allows the user to setup a profile ahead of time with the following
parameters (refer to Figure 51 and Figure 52). This is much more efficient since the
user can select or create the profile and select RUN to execute the automated leak
test and return when the ATP Leak Test has completed to review the leak test
results.
Figure 51
Selecting ATP Leak Test Profile