Bard WH183 Скачать руководство пользователя страница 18

Manual    2100-373
Page        16

     F

        R

     F

        R

     F

             R

-25.0
-24.0
-23.0
-22.0
-21.0
-20.0
-19.0
-18.0
-17.0
-16.0
-15.0
-14.0
-13.0
-12.0
-11.0
-10.0

-9.0
-8.0
-7.0
-6.0
-5.0
-4.0
-3.0
-2.0
-1.0

0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0

10.0
11.0
12.0
13.0
14.0
15.0
16.0
17.0
18.0
19.0
20.0
21.0
22.0
23.0
24.0

196871
190099
183585
177318
171289
165487
159904
154529
149355
144374
139576
134956
130506
126219
122089
118108
114272
110575
107010
103574
100260

97064
93981
91008
88139
85371
82699
80121
77632
75230
72910
70670
68507
66418
64399
62449
60565
58745
56985
55284
53640
52051
50514
49028
47590
46200
44855
43554
42295
41077

25.0
26.0
27.0
28.0
29.0
30.0
31.0
32.0
33.0
34.0
35.0
36.0
37.0
38.0
39.0
40.0
41.0
42.0
43.0
44.0
45.0
46.0
47.0
48.0
49.0
50.0
51.0
52.0
53.0
54.0
55.0
56.0
57.0
58.0
59.0
60.0
61.0
62.0
63.0
64.0
65.0
66.0
67.0
68.0
69.0
70.0
71.0
72.0
73.0
74.0

39898
38757
37652
36583
35548
34545
33574
32634
31723
30840
29986
29157
28355
27577
26823
26092
25383
24696
24030
23384
22758
22150
21561
20989
20435
19896
19374
18867
18375
17898
17434
16984
16547
16122
15710
15310
14921
14544
14177
13820
13474
13137
12810
12492
12183
11883
11591
11307
11031
10762

75.0
76.0
77.0
78.0
79.0
80.0
81.0
82.0
83.0
84.0
85.0
86.0
87.0
88.0
89.0
90.0
91.0
92.0
93.0
94.0
95.0
96.0
97.0
98.0
99.0

100.0
101.0
102.0
103.0
104.0
105.0
106.0
107.0
108.0
109.0
110.0
111.0
112.0
113.0
114.0
115.0
116.0
117.0
118.0
119.0
120.0
121.0
122.0
123.0
124.0

10501
10247
10000

9760
9526
9299
9077
8862
8653
8449
8250
8057
7869
7686
7507
7334
7165
7000
6840
6683
6531
6383
6239
6098
5961
5827
5697
5570
5446
5326
5208
5094
4982
4873
4767
4663
4562
4464
4367
4274
4182
4093
4006
3921
3838
3757
3678
3601
3526
3452

CHECKING TEMPERATURE SENSOR
OUTSIDE UNIT CIRCUIT.

1. Disconnect temperature sensor from outdoor coil.

2. Use an ohmmeter and measure the resistance of the

sensor.  Also use ohmmeter to check for short or
open.

3. Check resistance reading to chart of resistance use

ambient temperature.  (Tolerance of part is ± 10%.)

4. If sensor resistance reads very low, then sensor is

shorted and will not allow proper operation of the
heat pump control.

5. If sensor is out of tolerance, shorted, open or reads

very low ohms then it should be replaced

TEMPERATURE F VS RESISTANCE R OF TEMPERATURE SENSOR

Содержание WH183

Страница 1: ...T PUMP Models WH183 WH242 INSTALLATION INSTRUCTIONS Manual 2100 373A Supersedes 2100 373 File Volume III Tab 17 Date 05 13 02 Bard Manufacturing Company Bryan Ohio 43506 Since 1914 Moving ahead just a...

Страница 2: ...11 Figure 9 Start Up Procedure Decal 13 Figure 10 Defrost Control Board 14 Figure 11 Fan Blade Setting 17 Figure 12 Compressor Burnout Cleanup Procedure 13 Start Up 13 Important Installer Note 13 Cra...

Страница 3: ...and Summer Air Conditioning Duct Design for Residential ACCA Manual D Winter and Summer Air Conditioning and Equipment Selection For more information contact these publishers ACCA Air Conditioning Co...

Страница 4: ...ng inspection by the carrier s agent GENERAL The equipment covered in this manual is to be installed by trained experienced service and installation technicians The refrigerant system is completely as...

Страница 5: ...Manual 2100 373 Page 3 FIGURE 1 UNIT DIMENSIONS MIS 992...

Страница 6: ...ntion to note 89 of table 310 regarding Ampacity Adjustment Factors when more than 3 are in a raceway T I U C R I C E L G N I S l e d o M d e t a R s t l o V d n a e s a h P d l e i F o N r e w o P s...

Страница 7: ...wn to the unit base There are openings in the unit base for the drain hose to pass through In the event the drain hose is connected to a drain system of some type it must be an open or vented type sys...

Страница 8: ...shown in Figure 3 2 Locate and mark lag bolt locations and bottom mounting bracket location if desired See Figure 3 3 Mount bottom mounting bracket if used 4 Hook top rain flashing under back bend of...

Страница 9: ...Manual 2100 373 Page 7 FIGURE 3 MOUNTINGINSTRUCTIONS MIS 353...

Страница 10: ...Manual 2100 373 Page 8 FIGURE 5 WALLMOUNTINGINSTRUCTIONS SEE UNIT DIMENSIONS FIGURE 1 FOR ACTUAL DIMENSIONS MIS 548 MIS 549 FIGURE 4 WALLMOUNTINGINSTRUCTIONS SEE FIGURE 3 MOUNTING INSTRUCTIONS...

Страница 11: ...Manual 2100 373 Page 9 FIGURE 6 COMMONWALLMOUNTINGINSTALLATIONS MIS 550...

Страница 12: ...ly used heater sizes Also shown are the number of field power circuits required for the various models with heaters IMPORTANT NOTE Only the thermostat and subbase combinations as shown in Figure 7 wil...

Страница 13: ...e Figure 8 for compressor cutoff and outdoor thermostat wiring MIS 409 FIGURE 8 COMPRESSOR CUTOFF AND OUTDOOR THERMOSTAT WIRING 4 8 KW 1 Phase 6 KW 3 Phase TABLE 3 THERMOSTATWIRESIZE r e m r o f s n a...

Страница 14: ...d pressure etc that will prevent compressor from operating will cause green lamp to activate This is a signal to the operator of the equipment to place system in emergency heat position TABLE 4 WALLTH...

Страница 15: ...r The G indoor motor circuit is automatically completed on any call for cooling operation or can be energized by manual fan switch on subbase for constant air circulation IMPORTANT THESE PROCEDURES MU...

Страница 16: ...umper on the control This can be used to reduce the time between defrost cycle operation without waiting for time to elapse Use a small screwdr4iver or other metallic object or another 1 4 inch QC to...

Страница 17: ...g n i t a r r o t i c a p a c k c e h C d e t r o h s r o n e p o r o f k c e h C r o t i c a p a c r o t i c a p a c e c a l p e R l o r t n o c p m u p t a e H e v i t c e f e d n o y a l e r n a f...

Страница 18: ...17434 16984 16547 16122 15710 15310 14921 14544 14177 13820 13474 13137 12810 12492 12183 11883 11591 11307 11031 10762 75 0 76 0 77 0 78 0 79 0 80 0 81 0 82 0 83 0 84 0 85 0 86 0 87 0 88 0 89 0 90 0...

Страница 19: ...6 from compressor as shown in Table 7 The suction line temperatures in Table 7 are based upon 80 F dry bulb 67 F wet bulb 50 R H temperature and rated airflow across the evaporator during cooling cycl...

Страница 20: ...0 1 1 2 3 2 0 1 7 3 3 2 4 2 H W B D g e d 5 7 B W g e d 2 6 e d i S w o L e d i S h g i H 5 7 6 1 2 6 7 9 2 2 7 7 2 4 2 9 7 6 5 2 0 8 1 7 2 1 8 6 8 2 3 8 2 0 3 4 8 8 1 3 6 8 6 3 3 B D g e d 0 8 B W g...

Страница 21: ...t o M t s u a h x E h t i w r o t a l i t n e V m o o r s s a l C t s u a h x E h t i w r e z i m o n o c E r o t a l i t n e V y r e v o c e R y g r e n E X X X X X X X X X X X X X X X X X X X X X X...

Отзывы: