Manual   2100-366

Page    5

To turn gas control furnace knob OFF, turn
it to “OFF” position.  Use this same
procedure when you leave a vacation home
vacant and do not want the furnace to
operate.

4.A GAS AND ELECTRICAL SHUT-OFF

DEVICES

1.

GAS SHUT-OFF DEVICES

In an emergency, you may not be able to reach
all the gas shut-off devices.  You must know
how to turn off gas using any one of the three
manual types:

a. Manual Shut-off Switch on Gas Control

Gas control location is behind the access
panel on the right side.   See Lighting and
Shutdown Instructions in Section  5 for
more information.

b. Manual In-Line Shut-off Valve in Gas

Supply Line.

This valve could be next to furnace.
Figure 1 shows a typical installation.

Normally, gas is ON when you turn the
shut-off valve handle parallel to gas pipe.
Gas is OFF when you turn handle 90° from
gas pipe.

c. Manual Shut-off Valve at Natural Gas

Meter or Propane (LP) Gas Tank.

Normally, natural gas is ON when you turn
shut-off parallel to gas pipe.  Gas is OFF
when you turn shut-off 90° from gas pipe.
Some valves require a wrench or other
tools.

2.

ELECTRICAL SHUT-OFF DEVICES

In an emergency, you may not be able to reach
both of your electrical shut-off devices.
Therefore,you must know how to turn off
electricity using either one of them.  Here are
two types of electrical shut-off devices:

a. There should be an electrical shut-off

device located on or immediately adjacent
to the furnace.

b. There should be a separate circuit breaker

or fuse serving only the furnace located in
the main circuit breaker or fuse panel.
Know its location and make sure this device
is clearly identified.

In an emergency you 

must

 know how to turn off gas

and electricity.  Find out how 

before

 the emergency.

        WARNING

Should overheating occur or the gas
supply fail to shut off, shut off the manual
gas valve to the furnace before shutting off
the electrical supply.  Failure to do so can
cause a fire or explosion which could result
in damage, injury of death.

Содержание WG-Series

Страница 1: ...nditioner gas furnace for years of dependable service We re pleased you ve chosen our air conditioner gas furnace to supply your cooling heating needs Please keep this manual in a safe yet readily ava...

Страница 2: ...r Conditioning Start Up Procedure Crankcase Heater 12 Section 8 Ventilation Options 12 Section 9 Replacement Parts 13 Section 10 Outdoor Coil 13 Figures Figure 1 Typical Gas Piping 6 Figure 2 Step by...

Страница 3: ...____________ Model Number _______________________________________________________________ Serial Number _______________________________________________________________ Date Installed _________________...

Страница 4: ...s or vapors near or on your furnace These include gasoline kerosene cigarette lighter fluid cleaning fluids solvents paint thinners or painting compounds Flammable vapors can travel great distances be...

Страница 5: ...rs There is a 60 second delay after main burner is on until the comfort air blower starts on heating speed After the thermostat is satisfied the burners will go off as gas valve closes The inducer wil...

Страница 6: ...ut Alarm terminal on Compressor Control Module is 24V AC output connection for applications where signal is desired This terminal is powered whenever compressor is in manual lockout due to high pressu...

Страница 7: ...r or Propane LP Gas Tank Normally natural gas is ON when you turn shut off parallel to gas pipe Gas is OFF when you turn shut off 90 from gas pipe Some valves require a wrench or other tools 2 ELECTRI...

Страница 8: ...Manual 2100 366 Page 6 FIGURE 1 TYPICAL GAS PIPING MIS 1478...

Страница 9: ...condition indicates lack of airflow through furnace ACTION a Make sure air filter is clean and installed correctly b Check that registers and return air grilles are open and unobstructed c If conditio...

Страница 10: ...R FURNACE 1 Do not try to light main burners 2 Do not touch or turn on any electrical switch 3 Do not use any phone in your building 4 Immediately call your gas supplier from a neighbor s phone Follow...

Страница 11: ...Manual 2100 366 Page 9 FIGURE 2 START UP PROCEDURE...

Страница 12: ...of deterioration of the furnace 6 Periodic examinations of the vent terminal should also be conducted by the owner on a regular basis preferably every month but at least every two months during the he...

Страница 13: ...Manual 2100 366 Page 11 FIGURE 4 PERIODIC INSPECTIONS MIS 1449 FIGURE 3 FILTER LOCATIONS MIS 1447a...

Страница 14: ...is very important Please read carefully IMPORTANT These procedures must be followed at ini tial start up and at any time power has been removed for 12 hours or longer To prevent compressor damage whi...

Страница 15: ...ered by these instructions it is very important to always supply the complete model number and serial number of the unit This is necessary to assure that the correct parts or an approved alternate par...

Отзывы: