
Manual 2100-615A
Page
10 of 24
FIGURE 4
ELECTRIC HEAT CLEARANCE
W3RV2, W3LV2, W5RV2, W5LV2, W6RV2, W6LV2
WARNING
A
minimum
of 1/4 inch clearance must be maintained between
the supply air duct and combustible materials. This is required for
the first 3 feet of ducting.
It is important to insure that the 1/4 inch minimum spacing is
maintained at all points.
Failure to do this could result in overheating the combustible
material and may result in a fire causing damage, injury or death.
SIDE SECTION VIEW OF SUPPLY AIR DUCT FOR
WALL MOUNTED UNIT SHOWING 1/4 INCH CLEAR-
ANCE TO COMBUSTIBLE SURFACES.
Содержание W3LV2-R
Страница 2: ......
Страница 27: ......
Страница 34: ......
Страница 43: ......
Страница 46: ......
Страница 68: ......
Страница 74: ...Manual 2100 479 Page 6 of 11 FIGURE 1 TYPICAL AIR CONDITIONING SYSTEM COOLING CYCLE MIS 369...
Страница 75: ...Manual 2100 479 Page 7 of 11 FIGURE 2 TYPICAL HEAT PUMP SYSTEM COOLING CYCLE MIS 368...
Страница 80: ......
Страница 82: ...Manual 2110 1418G Page 2 of 16 CABINET COMPONENTS RIGHT EXTREME DUTY DOOR...
Страница 84: ...Manual 2110 1418G Page 4 of 16 CABINET COMPONENTS RIGHT MODERATE DUTY DOOR...
Страница 86: ...Manual 2110 1418G Page 6 of 16 CABINET COMPONENTS LEFT EXTREME DUTY DOOR...
Страница 88: ...Manual 2110 1418G Page 8 of 16 CABINET COMPONENTS LEFT MODERATE DUTY DOOR...
Страница 90: ...Manual 2110 1418G Page 10 of 16 FUNCTIONAL COMPONENTS RIGHT HAND This exploded view references table on page 12...
Страница 91: ...Manual 2110 1418G Page 11 of 16 FUNCTIONAL COMPONENTS LEFT HAND This exploded view references table on page 12...
Страница 97: ......
Страница 100: ......